Technical Information
55
S 500 & S 600 Canister Vacuums
4.9
Potentiometer and Indicator Light Removal (S 52x, S 62x)
1. Remove the casing top; see Section 020-4.2.
2. Remove the cap; see Section 030-4.1.
3. Remove the plug housing; see Section 030-4.7.
4. Use a screwdriver to release the indicator light locking tabs. See Figure 030-
17, Item 1. Remove the indicator light.
5. Use a screwdriver to release the 4 bracket locking tabs. See Figure 030-
17, Item 2. Remove the bracket.
Figure 030-17:
Indicator Light and Bracket (S 52x, S 62x)
6. Slide the cog wheel off the potentiometer.
7. Remove the potentiometer and cog wheel.
8. Replace the potentiometer and indicator light.
Summary of Contents for S 500 Series
Page 1: ...TECHNICAL INFORMATION S 500 and S 600 Canister Vacuums 2011 Miele USA ...
Page 17: ...Technical Information 17 S 500 S 600 Canister Vacuums 010 Casing Bottom ...
Page 25: ...Technical Information 25 S 500 S 600 Canister Vacuums 020 Casing Top ...
Page 42: ...Technical Information 42 S 500 S 600 Canister Vacuums 030 Operating Unit S 51x S 61x shown ...
Page 58: ...Technical Information 58 S 500 S 600 Canister Vacuums 040 Motor ...
Page 61: ...Technical Information 61 S 500 S 600 Canister Vacuums 050 Suction Hose ...
Page 63: ...Technical Information 63 S 500 S 600 Canister Vacuums 055 Electro Suction Hose S 558 S 658 ...