Connection for water recycling - PW 610x, PW 613x, PW 616x, PW 620x
–
Disconnect the machine from the electric mains supply provided in accordance with all relevant regulations and ensure utilities
cannot be switched on again in error. Carry out a check to ensure that no power is supplied to the machine.
–
Remove the screws on the left and right of the top of the lid.
–
Lift the front of the lid slightly, slide it to the rear and thus release the centring cones at the rear of the lid from the connection strip.
–
Remove the lid upwards.
–
Remove the rear panel.
–
Remove the mixer box cover plate on the rear of the machine, Fig. 1.
–
Loosen the hose clip on the drain hose and disconnect the hose, Fig. 2.
–
Drill out the water recycling intake on the mixer box to a diameter of approx. 28 mm, Fig. 4.
Warning!
Take care to collect and remove the drilling swarf at the mixer box drain outlet, Fig. 2.
–
Fit the water intake hose with hose clip on the mixer box connection stub and tighten the hose clip, Fig. 6.
–
Fit the mixer box cover plate with the throughfeed for the intake flange, Fig. 7.
–
Refit the mixer box drain hose on the mixer box drain outlet and tighten the hose clip.
Connection for water recycling - PW 6241, PW 6321
–
Disconnect the machine from the electric mains supply provided in accordance with all relevant regulations and ensure utilities
cannot be switched on again in error. Carry out a check to ensure that no power is supplied to the machine.
–
Remove the machine lid.
–
Remove the rear panel.
–
Remove the mixer box cover plate on the rear of the machine.
–
Pre-assemble the suds container / connection strip connection hose, Fig. 8.
Note
For the PW 6321 the hose must be shortened such that the dimension X1 = 80 mm.
–
The hose to the connection strip must be shortened such that the dimension X2 = 28.5 mm, Fig. 8.
–
Remove the blinding stopper on the suds container.
–
To secure the holder, Fig. 8, Pos. 1, drill a 6 mm hole in the suds container. Distance from rolled seam X = 110 mm, Fig. 9.
–
Lay the connection hose in the machine, Fig. 10.
–
Fit the angled connector and holder on the suds container, Fig. 11.
–
Pass the cover plate through the opening in the connection strip and fit it.
–
Fasten the connection hose with cable ties to the water intake hoses, Fig. 12.
Connection for water recycling - WS 5101, WS 5141, WS 5191, WS 5240, WS 5320
–
Disconnect the machine from the electric mains supply provided in accordance with all relevant regulations and ensure utilities
cannot be switched on again in error. Carry out a check to ensure that no power is supplied to the machine.
–
Remove the machine lid.
–
Remove the rear panel.
–
Remove the mixer box cover plate on the rear of the machine.
Produktgruppe 512
Umbau- und Montageanweisung
16 von 60
M.-Nr. 04598534
16.12.2011
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.