Supervisor level
79
Debounce time
In coin mode, the debounce time for
the minimum payment signal that
must be applied can be adjusted.
– Factory default: Short
For payment systems where the
falling coin generates the paid pulse.
– Long
For central control units on a 230 V
basis.
Payment system overriding time
Setting the transition signal for the
payment system. Security time margin
to prevent the payment system being
tampered with.
The transition time can be adjusted in
15-minute increments between 30–
240 minutes or switched off.
If the programme does not end within
the transition period, the setting in the
payment system is reset. The
programme is cancelled.
Factory setting: 180 minutes
Duration Cool air
The programme running time can be
adjusted.
A time between 10 and 120 minutes
can be set in 5-minute increments.
Factory setting: 120 minutes
Duration Warm air
The programme running time can be
adjusted.
A time between 20 and 120 minutes
can be set in 5-minute increments.
Factory setting: 60 minutes
FOC programmes
In coin mode, you can decide whether
the
Timed drying cool air
programme
can be used for free.
– Factory setting: Off
– On