Installation
*INSTALLATION*
64
If you wish to fit a grille in the ventila-
tion openings, the ventilation open-
ings must be larger than 31 square
inches. The passage volume of 31
square inches is the total area of the
opening slits in the grille.
– Important! The larger the ventilation
slits, the more economically the wine
conditioning will work.
The ventilation slits must not be
blocked or obstructed in any way.
Clean the ventilation slits on a regu-
lar basis.
Custom door panel
Horizontal and vertical gaps
Depending on the style of kitchen cabi-
netry, the thickness and edge radius of
the custom door panel and the gap that
runs around the door, vertically and hor-
izontally, are specified.
It is essential to pay attention to the
following:
–
Horizontal gap
The gap between the custom door
panel and the housing unit door above
or below it must be at least 1/8" (3 mm).
–
Vertical gap
If the gap between the custom door
panel and the adjoining housing unit
door or wall on the hinged side is too
small, the appliance door could col-
lide with the adjoining housing unit
door or wall when opened.
It may be necessary to adjust the
size of this gap to suit the thickness
and edge radius of the custom door
panel.
This must be taken into consideration
when planning your kitchen and when
replacing an old wine conditioning unit
with a new one to ensure the installation
conditions required are met.