Electrical connection
64
Risk of damage from incorrect
connection.
Unauthorised installation,
maintenance and repairs can cause
considerable danger for the user.
Miele cannot be held liable for
damage or injury caused by
unauthorised installation,
maintenance or repair work, or by an
inadequate or faulty on-site earthing
system (e.g. electric shock).
This hob must be connected to the
electrical supply by a qualified
electrician.
The electrician must be familiar with
and comply with the national
regulations and any additional
regulations of the local electricity
provider (e.g. BS 7671 in the UK).
After installation, ensure that all
electrical components are shielded
and cannot be accessed by users.
Total power rating
See data plate
Connection data
The connection data is quoted on the
data plate. Please ensure these match
the household mains supply.
Please see wiring diagrams for
connection. (N.B. This appliance is
supplied single phase only in the UK /
AUS / NZ).
Residual current device
For extra safety, it is advisable to
protect the appliance with a suitable
residual current device (RCD) with a trip
range of 30 mA.
WARNING
THIS APPLIANCE MUST BE
EARTHED
Disconnecting devices
It must be possible to disconnect the
hob from the mains at all poles using
disconnecting devices! A contact
distance of at least 3 mm must be
observed in the switched-off state! The
disconnecting devices are overcurrent
protection devices and residual current
protection devices.