Cleaning the drain pump and
non-return valve
If water has not been pumped away at
the end of a programme the drain
pump or the non-return valve might be
blocked. They are however, easy to
clean.
^
Take the filter combination out of the
wash cabinet.
^
Release the locking clamp.
^
Lift up the non-return valve and rinse
under running water.
The drain pump is situated under the
non-return valve (see arrow).
^
Before replacing the non-return valve
check that the drain pump is free of
obstructions.
^
Carefully replace the ron-return valve
and secure with the locking clamp.
Cleaning and care
49
Summary of Contents for G 7882