1.2 DOS 3 (Neutralising agent)
1.2.1 Setting the dosage concentra-
tion:
Set the dosage concentration accord-
ing to the neutralising agent manufac-
turer’s recommendations.
Example: If the manufacturer recom-
mends a concentration level of 0.3 %
set the value to 0.30.
^
Turn the programme selector to the
CHEM 60°C-5’
position. The dosage
concentration set will appear as a %
in the display:
0.05 - 0.50 = 0.05 % - 0.5 % dosage
concentration.
^
Press
ß
as many times as neces-
sary or hold it pressed in until the re-
quired value appears.
The dosage concentration is now set.
Value set:
1.2.2 Venting the dispensing system:
a) After setting the dosage concentra-
tion:
^
Turn the programme selector to the
6
position. "do3" appears in the dis-
play.
^
Press
ß
.
The dispensing system will be vented
automatically. 0 will appear in the dis-
play when venting is finished.
Having changed a value or all values:
^
Press the
6
button. SP appears.
^
Press
6
again. The change has
been recorded.
b) If only venting is required (e.g. be-
cause the dispensing system has been
allowed to empty by mistake)
^
Select programming level 2 (see
1.
).
Then proceed as follows:
^
Turn the programme selector to the
6
position. "do3" appears in the dis-
play.
^
Press
ß
.
The dispensing system will be vented
automatically. 0 will appear in the dis-
play when venting is finished.
^
Switch the machine off with the
I-0
button.
Every time the dispensing system has
been vented:
Run the PRE-RINSE programme
D
so
that after venting any agents in the
wash cabinet are diluted before being
drained away.