82 CropHawk Draper Platform Operators Manu-
Trouble Shooting
Continued on next page
Symptom
Problem
Solution
Reference
REEL SYMPTOMS
Reel wrapping in tangled and
weedy conditions
Incorrect reel location
Reel speed too fast
Adjust reel forward and down
Slow reel until crop flows smoothly onto
belts
Reel carrying around material
Reel speed excessive
Reel height is to low
PU finger pitch is to aggressive
Reel is positioned to far back
Adjust reel speed to be slightly faster
than ground speed so reel moves crop
gently and evenly.
Raise reel to reduce the amount of straw
gathered by the reel.
Adjust PU finger pitch to reduce aggres-
sion and the amount of straw gathered by
the reel.
Move reel forward to suit conditions.
Reel stalls in heavy material
Reel relief valve setting, to low
Reel to low
Adjust reel relief setting to suit heavy
crop conditions.
Raise reel
Reel speed will not adjust
Combine driven system
Platform driven system
Combine electrical fault
Reel relief valve setting, to low.
No power supply to platform reel
speed control valve.
See combine operators manual.
Adjust relief valve setting.
Refer to combine operators manual.
Reel will not turn
Combine control set at zero.
Hydraulic coupling not
connected properly.
Drive line failure.
Reel drive hoses connected to
Set control to desired setting.
Check hydraulic combine connection.
Inspect reel drive chain. Repair or re-
place if required. Check reel drive
sprocket keyways. Replace if required.
Reel goes out of phase
When reel lift cylinder are
repeatedly operated near fully
closed position, it is normal for
lift cylinders to get out of phase.
Air in the reel lift circuit.
Reel lift cylinder seal damaged.
Re-phase lift cylinders at bottom of
stroke.
Bleed air form reel lift cylinders.
Replace reel lift cylinder seal kit.
Reel will not lift
Reel lift hydraulic couplers are
not properly connected.
Combine electrical fault.
Check hydraulic combine connection.
See combines operators manual.
Reel fore & aft will not function
Reel lift hydraulic couplers are
not properly connected.
Combine electrical fault.
Check hydraulic combine connection.
See combines operators manual.