Touchmaster
®
Conversion Kit
Setup - 17
INVERTING TOUCHSCREEN SIGNALS
1. Turn off AC power and unplug the line cord.
2. Open the cabinet door.
3. Locate the P2 connector on
the CPU Board Assembly (at
the J6 designation) and
remove the connector from
the socket.
CONNECTOR P2 ON CPU BOARD ASSEMBLY
4. Using your fingers, pry off
the plastic strain relief cap.
Set the cap aside in a safe
place.
REMOVAL OF CONNECTOR CAP
5. Remove the first wire (it will
be blue with a white stripe).
Replace the cap and close it
tightly.
REMOVAL OF BLUE AND WHITE WIRE
6. Insulate the blue, white-striped wire and secure it to the harness.
7. Reattach connector P2 to the CPU Board Assembly at J6.
8. Replace the electronics into the cabinet.
9. Close the cabinet door. Plug in the line cord. Turn ON the AC power.
10. Recalibrate the VGM.
HEAT SINK
P2 CONNECTOR
FRONT OF
CABINET
FIRST WIRE
BLUE AND
WHITE WIRE