Chapter 10: Maintenance / Troubleshooting

Handling the Test Cables

 

Always connect and disconnect the clamps to the battery 

by opening and closing the clamps. Never pull on the test 

cables to remove the battery clamps. Pulling can damage 

the Y-junction, the cables, and the clamps to the extent 

that the analyzer may produce lower-than-expected con-

ductance readings or fail completely.

 

Never carry the analyzer by the cables. Carrying the ana-

lyzer or swinging it by the cables puts unnecessary strain 

on the cables and can result in premature failure. Handle 

the analyzer with care to get the maximum use from the 

product.

 

Never wrap the cables around the analyzer; this puts un-

necessary strain on the test cables.

Test cables they have a certain life expectancy and will wear 

out eventually. To ensure the best performance and longest 

life of the test cables, attach and remove them with care, and 

carry the analyzer and cables together.

 IMPORTANT: Test cables that have been abused are 

not covered under the Midtronics warranty. 

If an inspection or a change in test results indicate that the test 

cables need to be replaced, please call Midtronics Customer 

Service at 1-630-323-2800.

Troubleshooting

In addition to the troubleshooting suggestions in this chapter, 

the tester Help Menu provides tips on troubleshooting 

problems with the printer, the cables, and loss of power. It also 

includes Midtronics Customer Service phone numbers. 

Problems with the Display

The display does not turn on:

 

Check the connection to the battery.

 

The analyzer’s internal batteries may need to be replaced. 

The display flickers or is dim:

 

The contrast may need to be adjusted in the Admin menu. 

Highlight the Display icon and press ENTER. Use 

 or 

 

to scroll the contrast value to 10.

 

The analyzer’s internal batteries may need to be replaced. 

Problems with the Internal Printer

The internal printer will not print:

 

The analyzer must be connected to the vehicle battery to 

print to the internal printer. Check the clamp connections 

to the battery.

 

The vehicle battery may be too low to power the printer. 

Connect to a battery with at least 11.5 volts.

 

Verify that the paper is properly installed.

 

Verify that the paper sensor is clean and undamaged.

Summary of Contents for EXP-802

Page 1: ...For testing 6 and 12 volt automotive batteries and 12 and 24 volt charging systems INSTRUCTION MANUAL EXP 803 Battery Electrical Diagnostic Analyzer March 2013 167 000495EN A...

Page 2: ...blank page behind cover...

Page 3: ...ages 12 System Noise Detected 12 Unstable Battery Detected 12 Deep Scan Test 12 Voltage Out of Range 12 Battery Test Results 12 State of Health SOH 13 Chapter 4 System Test 14 Battery Test 14 Starter...

Page 4: ...Power Indicator 25 Replacing the Internal Batteries 25 Clamps 25 Cleaning the Clamps 25 Handling the Test Cables 26 Troubleshooting 26 Problems with the Display 26 The display does not turn on 26 The...

Page 5: ...start servicing the battery Use caution when working with metallic tools to prevent sparks or short circuits Never lean over a battery when testing charging or jump starting Risk of explosive gases Ne...

Page 6: ...yzer align the arrow on the cableconnectorwiththe arrows on the analyzer s housing Hold the part of the cable connector as shown and firmly insert the connector into analyzer s six pin receptacle Do n...

Page 7: ...ows you whether the screen is the top or only screen middle or last in a series Top screen Middle screen Last screen Scroll Box Arrow keys Press the key to move up to the next selectable item or row W...

Page 8: ...ccession without re entering battery information each time Utility to view and print test results a test counter a data transfer utility and information on the analyzer software version and serial num...

Page 9: ...bles you to set the language for the display and printed test results You can disable this option in the Admin Menu 1 Use or to select which language should be used on the tester screen 1 ENGLISH 2 ES...

Page 10: ...When testing side post or Group 31 batteries always use lead terminal adapters provided with the tester do not test at the battery s steel bolts To avoid damage never use a wrench to tighten the adapt...

Page 11: ...hicle Press NEXT to continue 3 Use or to select the POST TYPE and press NEXT to continue 1 TOP POST 2 SIDE POST 3 JUMP START POST System Test only Press NEXT to continue 4 Use or to select the APPLICA...

Page 12: ...n The analyzer will automatically retest when it no longer detects system noise If the message reappears You may be testing too close to a noise source such as a charger or other high current device I...

Page 13: ...BATTERY Return the battery to service GOOD RECHARGE Fully charge the battery and return it to service CHARGE REQUIRED Fully charge the battery using a Midtronics Diagnostic Charger and retest Failure...

Page 14: ...System Decisions Decision Action CRANKING NORMAL The starter voltage is normal and the battery is fully charged LOW VOLTAGE The starter voltage is low and the battery is fully charged CHARGE BATTERY T...

Page 15: ...DC voltage range Bar graph showing DC voltage within normal range with loads on and off Graph of diode waveform Peak to peak AC voltage Charging System Decisions Decision Action NO PROBLEMS The system...

Page 16: ...12 80v 5 For the next few seconds the tester evaluates the battery writes the results to the data card and displays the results starting from the last battery tested To view a previous re sult for a b...

Page 17: ...e selected battery Select option 2 to print the results of all the bat teries listed by the date and order in which they were test ed Select PRINT 1 INVENTORY BATTERY 2 INVENTORY SUMMARY Totals The TO...

Page 18: ...the tester boots up and when you print test results ADMIN OPTIONS 1 USER ID User login screen enabled ON 2 UNREG USER Unregistered user accessibility enabled ON 3 PRINTER HEADER Prints address header...

Page 19: ...nes of your shop information Users The USERS utility allows you to create and edit a USER ID with 1 to 7 alphanumeric characters and link it to a test counter It also allows you to delete a USER ID an...

Page 20: ...me Backlight time is from 0 to 30 seconds To change it 1 Use or to select BACKLIGHT TIME CONTRAST LEVEL 10 BACKLIGHT TIME 60 2 Press ADJUST to display the option s numerical scroll box 15 SEC 3 Press...

Page 21: ...ackets that define the data NOTE To avoid corrupting the file copy rather than move the file to your PC The default setting for the utility is OFF 1 To change the setting use or to make your selection...

Page 22: ...ill not clear the lifetime test total avail able in the VERSION information screen Reset Defaults This function allows you to reset Administrative options to their original settings It will clear all...

Page 23: ...diameter Replacement rolls are available at most office supply stores NOTE Due to production variances some paper roll diameters may be too large Please remove paper from roll to recommended 17 8 inc...

Page 24: ...ile These data fields will be displayed as the header row in your spreadsheet application STORE ID Entered by user TIME Time of test DATE Date of test LOCATION Tested in vehicle or out of vehicle MEAS...

Page 25: ...b 3 Lift the door at the tab and place it aside 4 Remove the discharged batteries 5 Insert new batteries as shown Make sure the positive and negative terminals are positioned correctly 6 Reposition th...

Page 26: ...ve been abused are not covered under the Midtronics warranty If an inspection or a change in test results indicate that the test cables need to be replaced please call Midtronics Customer Service at 1...

Page 27: ...efore entering it into the Battery Diagnostic Station Header Template Line 1 Line 2 Line 3 Line 4 Line 5 Line 6 Line 7 Line 8 Line 9 Line 10 Line 11 Line 12 Coupon Template To help you edit and center...

Page 28: ...or to modify the cable assembly SERVICE To obtain service contact Midtronics at 1 630 323 2800 Have your model and serial numbers ready This first step is critical as we will trouble shoot the proble...

Reviews: