background image

Midtronics Inc.     7000 Monroe Street     Willowbrook, IL 60527

www.midtronics.com

19

EXP-803

Chapter 7: Admin Menu

Shop

 The SHOP utility allows you to create a header for 

your printed test results with your business location 

information when the Admin option 3-PRINT HEADER 

is selected.

1.  Press 

 or 

 to highlight the line you want to change. 

Press SELECT to edit the selected line. The cursor blinks to 

the right of the last character in the line. (The cursor is not 

visible if all character spaces are filled.)

2.  To erase a character, press 

.

3.  Display a character by pressing 

 or 

 as many times 

as needed. You can center text by inserting blank spaces 

with the 

 key.

 IMPORTANT: Be sure to erase any default charac-

ters on unused lines by pressing the 

 key.

4.  To save your text on the selected line, press SAVE.

  NOTE: The right soft key displays SELECT when 

you highlight a line for editing and SAVE when 

you edit the line. To exit the edit mode of the 

selected line without saving the changes, press 

BACK.

Screen 1

Screen 2

1–YOUR SHOP NAME

5–YOUR COUNTRY

2–1000 ANY STREET

6–YOUR PHONE NUMBER

3–YOUR TOWN, STATE

7–WWW.WEBSITE.COM

4–YOUR ZIP CODE

8–

5.  Press  SAVE to save your edited line and return to the 

SHOP INFO screen.  Repeat the process to edit the addi-

tional lines of your shop information.

Users

  The USERS utility allows you to create and edit a USER 

ID with 1 to 7 alphanumeric characters and link it to a 

test counter. It also allows you to delete a USER ID and 

its associated test total.

Entering a New User ID

1.  Use 

 or 

 to select ENTER NEW.

  ENTER NEW

  DELETE

  EDIT

Press NEXT to display the list of available IDs. 

2.  Use 

 or 

 to scroll to the ID placeholder you want to use. 

Scrolling past the first line displays the previous screen. 

Scrolling past the fourth line displays the next screen. To 

display more placeholders, continue scrolling or use 

 or 

 to jump up or down through the list five lines at a time.

1 USER01

2 USER02
3 USER03
4 USER04

Press NEXT to continue.

3.  To clear the default characters, press 

. To add a space, 

move the cursor forward by pressing 

.

ENTER USER ID

USER01

4.  Display a character by pressing 

 or 

 as many times as 

needed. Press SAVE to continue.

ENTER USER ID

ORLANDO

Deleting a User ID

  NOTE: You cannot delete placeholder USER IDs  

(i.e., USER03).

1.  Use 

 or 

 to select DELETE.

  ENTER NEW

  DELETE

  EDIT

Press NEXT to display the list of IDs. 

2.  Use 

 or 

 to scroll to the ID placeholder you want to use. 

Scrolling past the first line displays the previous screen. 

Scrolling past the fourth line displays the next screen. To 

display more placeholders, continue scrolling or use 

 or 

 to jump up or down through the list five lines at a time.

1 ORLANDO

2 DAN C
3 JASON
4 USER04

Press DELETE to continue.

Summary of Contents for EXP-802

Page 1: ...For testing 6 and 12 volt automotive batteries and 12 and 24 volt charging systems INSTRUCTION MANUAL EXP 803 Battery Electrical Diagnostic Analyzer March 2013 167 000495EN A...

Page 2: ...blank page behind cover...

Page 3: ...ages 12 System Noise Detected 12 Unstable Battery Detected 12 Deep Scan Test 12 Voltage Out of Range 12 Battery Test Results 12 State of Health SOH 13 Chapter 4 System Test 14 Battery Test 14 Starter...

Page 4: ...Power Indicator 25 Replacing the Internal Batteries 25 Clamps 25 Cleaning the Clamps 25 Handling the Test Cables 26 Troubleshooting 26 Problems with the Display 26 The display does not turn on 26 The...

Page 5: ...start servicing the battery Use caution when working with metallic tools to prevent sparks or short circuits Never lean over a battery when testing charging or jump starting Risk of explosive gases Ne...

Page 6: ...yzer align the arrow on the cableconnectorwiththe arrows on the analyzer s housing Hold the part of the cable connector as shown and firmly insert the connector into analyzer s six pin receptacle Do n...

Page 7: ...ows you whether the screen is the top or only screen middle or last in a series Top screen Middle screen Last screen Scroll Box Arrow keys Press the key to move up to the next selectable item or row W...

Page 8: ...ccession without re entering battery information each time Utility to view and print test results a test counter a data transfer utility and information on the analyzer software version and serial num...

Page 9: ...bles you to set the language for the display and printed test results You can disable this option in the Admin Menu 1 Use or to select which language should be used on the tester screen 1 ENGLISH 2 ES...

Page 10: ...When testing side post or Group 31 batteries always use lead terminal adapters provided with the tester do not test at the battery s steel bolts To avoid damage never use a wrench to tighten the adapt...

Page 11: ...hicle Press NEXT to continue 3 Use or to select the POST TYPE and press NEXT to continue 1 TOP POST 2 SIDE POST 3 JUMP START POST System Test only Press NEXT to continue 4 Use or to select the APPLICA...

Page 12: ...n The analyzer will automatically retest when it no longer detects system noise If the message reappears You may be testing too close to a noise source such as a charger or other high current device I...

Page 13: ...BATTERY Return the battery to service GOOD RECHARGE Fully charge the battery and return it to service CHARGE REQUIRED Fully charge the battery using a Midtronics Diagnostic Charger and retest Failure...

Page 14: ...System Decisions Decision Action CRANKING NORMAL The starter voltage is normal and the battery is fully charged LOW VOLTAGE The starter voltage is low and the battery is fully charged CHARGE BATTERY T...

Page 15: ...DC voltage range Bar graph showing DC voltage within normal range with loads on and off Graph of diode waveform Peak to peak AC voltage Charging System Decisions Decision Action NO PROBLEMS The system...

Page 16: ...12 80v 5 For the next few seconds the tester evaluates the battery writes the results to the data card and displays the results starting from the last battery tested To view a previous re sult for a b...

Page 17: ...e selected battery Select option 2 to print the results of all the bat teries listed by the date and order in which they were test ed Select PRINT 1 INVENTORY BATTERY 2 INVENTORY SUMMARY Totals The TO...

Page 18: ...the tester boots up and when you print test results ADMIN OPTIONS 1 USER ID User login screen enabled ON 2 UNREG USER Unregistered user accessibility enabled ON 3 PRINTER HEADER Prints address header...

Page 19: ...nes of your shop information Users The USERS utility allows you to create and edit a USER ID with 1 to 7 alphanumeric characters and link it to a test counter It also allows you to delete a USER ID an...

Page 20: ...me Backlight time is from 0 to 30 seconds To change it 1 Use or to select BACKLIGHT TIME CONTRAST LEVEL 10 BACKLIGHT TIME 60 2 Press ADJUST to display the option s numerical scroll box 15 SEC 3 Press...

Page 21: ...ackets that define the data NOTE To avoid corrupting the file copy rather than move the file to your PC The default setting for the utility is OFF 1 To change the setting use or to make your selection...

Page 22: ...ill not clear the lifetime test total avail able in the VERSION information screen Reset Defaults This function allows you to reset Administrative options to their original settings It will clear all...

Page 23: ...diameter Replacement rolls are available at most office supply stores NOTE Due to production variances some paper roll diameters may be too large Please remove paper from roll to recommended 17 8 inc...

Page 24: ...ile These data fields will be displayed as the header row in your spreadsheet application STORE ID Entered by user TIME Time of test DATE Date of test LOCATION Tested in vehicle or out of vehicle MEAS...

Page 25: ...b 3 Lift the door at the tab and place it aside 4 Remove the discharged batteries 5 Insert new batteries as shown Make sure the positive and negative terminals are positioned correctly 6 Reposition th...

Page 26: ...ve been abused are not covered under the Midtronics warranty If an inspection or a change in test results indicate that the test cables need to be replaced please call Midtronics Customer Service at 1...

Page 27: ...efore entering it into the Battery Diagnostic Station Header Template Line 1 Line 2 Line 3 Line 4 Line 5 Line 6 Line 7 Line 8 Line 9 Line 10 Line 11 Line 12 Coupon Template To help you edit and center...

Page 28: ...or to modify the cable assembly SERVICE To obtain service contact Midtronics at 1 630 323 2800 Have your model and serial numbers ready This first step is critical as we will trouble shoot the proble...