CONTROL PADS ON THE DEHUMIDIFIER

Control pads

When you push the button to change
operation modes, the unit will make
a beep sound to indicate that it is
changing modes.

NOTE: The control panel of the unit you purchased may be slightly different according to the
models.

Fig.1

Humidity Set Control Pads

: Down/Up Pads

TIMER Set Control Pads

Use the Up/Down pads to set the Auto
start and Auto stop time from 0.0 to 24.

The humidity level can be set within a range of
35%RH(Relative Humidity) to 85%RH(Relative
Humidity) in 5% increments.
For drier air, press the      pad and set to a lower
percent value(%).
For damper air, press the      pad and set  a higher
percent value(%).

CONTROL PADS ON THE DEHUMIDIFIER

Other features

Bucket Full Light

Glows wh en the b ucket  i s ready to b e
emptied .

Whe n fros t bu ilds up on the evaporator coil s, the
co mpressor wi ll cycle o ff and the fan wi ll conti nue
to run u ntil the fro st d isa ppears.

Auto Defrost

Wait 3 minutes before res uming operation

After the u nit h as stop ped,  it can not be re start
ope rtation in the first 3 minute s. Thi s i s to prote ct
the uni t. Operatio n will automatical ly start a fter
3 minu tes.

Setting the Timer

 When the unit is on, first  pre ss the Timer
 button,  the Timer Off indicator light
 illuminates. It indicates the Auto Stop
 program is in itiated. Press it aga in the
 Time On indecator light illuminates.It
 indicates the Auto Start is initiated.

 Press or hold the UP or DOWN pad to
 change the Auto time by 0.5 hour incre-
 ments,  up to 10 hours, the n at 1 hour
 increments u p to 24 hours. The co ntrol
 will coun t down the time remaining until
 start.
 The selected time will register in 5 seconds
 and the system will automatically revert
 back to display the previous humidity
 setting.
 When the Auto start & Auto stop times are
 set, within th e same program sequence,
 TIMER ON OFF indicato r lights illum inate
  identifying both ON and OFF times are
  now programmed.
 Turning the unit ON or OFF at an y time or
 adjusting the timer setting to 0.0 will cancel
 the Auto Start/Stop function.
 When LED display window displays the
 code of  P2, the Auto Sta rt/Stop function
 will also be cancelled.

When the unit is off, first  press the Timer

 button, the TIMER ON indicator light
 illuminates. It indicates the Auto Start
 program is in itiated. Press it aga in the
 Time Off indecator ligh t illuminates.It
 indicates the Auto Stop is initiated.

Check filter feature

The system starts to count the time once th e fa n
mo tor op erates. The che ck filter featu re ca n be
onl y a ctivated when the accumulated ope ra tion
time achie ves 250 hours o r mo re . The Reset
 light(Clean filter ind icator lig ht) fla she s a t one time
per sec ond, after finis hing cl ean the air fi lter, p ress
the Filte r pad and the Rese t light(Clean filter indi cato r
lig ht) go es off.

Display

Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
(

5% accuracy) room % humidity level in a range of

- Humidity sensor error--Unplug the unit and plug it back

       in. If error repeats, call for service.

±

30%

RH(Relative Humidity) to 90%RH(Relative Humidity).

Error Codes and Protection Code:
AS

Auto Shut Off

The  

shu ts 

o ff  

when 

the 

buc ket  

is

full, or wh en the b ucket is remove d or not re placed
in the prope r position .When the setting h umi dity is
reached, the unit will be shut off au toma tically.
For some model s,the fan mot or will continue
operating .

deh umi difier

Auto-Restart

If the unit breaks off unexpectedly due to the power cut,
it will restart with the previous function setting automa-
tically when the power resumes.

PUMP  Pad(on some models)

Press to activate the pump operation.
NOTE: Make sure the pump drain hose is installed
into the unit and the continuous drain hose is removed
from the unit before the pump operation is activated.
When the bucket is full,the pump starts to work.Refer
to the next pages for removing the collected water.
Do not use this operation when the outdoor temperature
is equel to or less than 0 C (32 F).

O

O

POWER Pad

Press to turn the dehumidifier on and off.

TIMER Pad

Press to initiate the Auto start and Auto stop feature,
in conjuction with the       and         pads.

E3

- Unit malfunction-- Unplug the unit and plug it back in. If

      error repeats, call for service.

Eb

- Bucket is removed or not in right position-- Replace the

       bucket in the right position.

Auto defrost operation on
indicator light

TIMER

Clean filter
indicator light

Bucket full
indicator light

Pump operation
on indicator light

Continuous
operation on
indicator light

On
Off

Defrost

Full

CONT.

POWER

PUMP

COMFORT

FILTER

TURBO

ION

Timer on/off
indicator light

High fan
indicator light

Ion operation
indicator light

Comfort dehumidifying
operation on
indicator light

TURBO Pad

Control the fan speed. Press to select either High
or Normal fan speed. Set the fan control to High for
maximum moisture removal. When the humidity has
been reduced and quiet operation is preferred, set
the fan control to Normal.

 FILTER Pad

The check filter feature is a reminder to clean the
Air Filter for more efficient operation. The Filter
light(Clean filter l ight) will illuminate after 250 hours
of operation. To reset after cleaning the filter, press
the Filter pad and the light will go off.

Press to activate the comfort dehumidifying operation.
NOTE: On this operation,the unit can not be set
humidity level.

 COMFORT Pad(optional)

ION Pad(optional)

Press to activate the ionizer. Anions ar automatically
generated by ionization. The anions deactive the
airborne chemical vapors and dust particles. Press
it again to stop the function.

 CONTINUE Pad

Press to activate the continuous dehumidifying operation.

- Temperature sensor error-- Unplug the unit and plug it

       back in. If error repeats, call for service.

- Bucket is full -- Empty the bucket.

ES

P2

Summary of Contents for PAD60P1AGR

Page 1: ...pecifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Before operating this product please read the instructions carefully and save this manual for future use ...

Page 2: ...erly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all Read This Manual CAUTION This appliance can be used by children aged from 8 years and above...

Page 3: ...Do not cover the intake or exhaust openings with cloths or towels A lack of air flow can lead to overheating and fire Never insert your finger or other foreign objects into grills or openings Take special care to warn children of these dangers Do not use in areas where chemicals are handled This will cause the unit deterioration due to chemicals and solvents dissolved in the air Care should be tak...

Page 4: ...Shows the set humidity level from 35 to 85 or auto start stop time 0 24 while setting then shows the actual 5 accuracy room humidity level in a range of Humidity sensor error Unplug the unit and plug it back in If error repeats call for service 30 RH Relative Humidity to 90 RH Relative Humidity Error Codes and Protection Code AS Auto Shut Off The shuts off when the bucket is full or when the bucke...

Page 5: ...ttom of unit Casters can move freely Do not force casters to move over carpet nor move the unit with water in the bucket The unit may tip over and spill water A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area such as a closet unless there is adequate circulation of air in and out of the area Air outlet grille Air intake grille 20cm or ...

Page 6: ... hose into the pump drain hose outlet for depth of 15mm at least See Fig 11 then lead the water hose to the floor drain or a suitable drainage facility Press the pump pad of the unit to activated the pump operation When the bucket is full the pump starts to work NOTE The pump may cause big noise when it starts to work for 3 5 minutes It is a normal phenomenon Pump drain hose Pump drain hose outlet...

Page 7: ... pump Check the pump hose does not link or block Empty the water of the bucket 3 Clean the air filter Remove the filter every two weeks based on normal operating conditions To remove the filter pull filter outwards See Fig 14 Wash the filter with clean water then dry Re install the filter replace Bucket DO NOT operate the dehumidifier without a filter because dirt and lint will clog it and reduce ...

Page 8: ......

Reviews: