IDENTIFICATION OF PARTS

Power Cord and plug

Continuous drain hose outlet

Band(Used only when
storing the unit.)

Front

Rear

Air outlet grille

Caster

Identification of par ts

Control panel

Water bucket

1
2
3
4

1
2

3

4

NOTE:

All the pictures in the manual are

for explanation purposes only. The actual
shape of the unit you purchased may be
slightly different, but the operations and
functions are the same.

OPERATING THE UNIT

When using the unit

 When first using the dehumidifier, operate the unit
 continuously 24 hours. Make sure the plastic cover on
 the continuous drain hose outlet install stightly properly
 so there are no leaks.

This unit is designed to operate with a working
environment between 5 C/41 F and 35 C/95 F.
If the unit has been switched off and needs to be
switched on again quickly, allow approximately
three minutes for the correct operation to resume.
Do not connect the dehumidifier to a multiple socket
outlet, which is also being used for other electrical
appliances.
Select a suitable location, making sure you have easy
access to an electrical outlet.
Plug the unit into a  electrical socket-outlet with earth
connection.
Make sure the Water bucket is correctly fitted otherwise
the unit will not operate properly.

When the water in the bucket reaches to a certain

level,please be careful to move the machine to avoid it
falling down.

O

O

O

O

NOTE:

Casters(At four points on the bottom of unit)

Casters can  move freely.

    Do not force casters to move over carpet,
    nor move the unit with water in the bucket.
    (The unit may tip over and spill water.)

 A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed
 storage area, such as a closet, unless there is adequate circulation of air in and out of the area.

Air outlet grille

Air intake
grille

20cm or more

20cm or more

20cm or more

20cm or more

40cm or
more

Positioning the unit

 Do not use outdoors.
 This dehumidifer is intended for indoor residential
 applications only. This dehumidifier should not be used
 for commercial or industrial applications.
 Place the dehumidifier on a smooth, level floor strong
 enough to support the unit with a full bucket of water.
 Allow at least 20cm of air space on all sides of the unit
 for good air circulation

.

 Place the unit in an area where the temperature will not
 fall below 5 C(41 F). The coils can become covered with
 frost at temperatures below 5 C(41 F), which may reduce
 performance.
 Place the unit away from the clothes dryer, heater or radiator.
 Use the unit to prevent moisture damage anywhere books
 or valuables are stored.
 Use the dehumidifier in a basement to help prevent
  moisture damage.
 The dehumidifier must be operated in an enclosed
 area to be most effective.
 Close all doors, windows and other outside openings
 to the room.

(at least 40cm of air space on

 air outlet).

Fig.4a

Accessories:

pump drain hose(1pc)(only for the unit with pump feature)

Handle (both sides)

Pump drain hose outlet(some models without)

5

Fig.2

Fig.3

1

2

3

4

1

2

3

6

Air intake filter

Summary of Contents for PAD60P1AGR

Page 1: ...pecifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Before operating this product please read the instructions carefully and save this manual for future use ...

Page 2: ...erly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all Read This Manual CAUTION This appliance can be used by children aged from 8 years and above...

Page 3: ...Do not cover the intake or exhaust openings with cloths or towels A lack of air flow can lead to overheating and fire Never insert your finger or other foreign objects into grills or openings Take special care to warn children of these dangers Do not use in areas where chemicals are handled This will cause the unit deterioration due to chemicals and solvents dissolved in the air Care should be tak...

Page 4: ...Shows the set humidity level from 35 to 85 or auto start stop time 0 24 while setting then shows the actual 5 accuracy room humidity level in a range of Humidity sensor error Unplug the unit and plug it back in If error repeats call for service 30 RH Relative Humidity to 90 RH Relative Humidity Error Codes and Protection Code AS Auto Shut Off The shuts off when the bucket is full or when the bucke...

Page 5: ...ttom of unit Casters can move freely Do not force casters to move over carpet nor move the unit with water in the bucket The unit may tip over and spill water A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area such as a closet unless there is adequate circulation of air in and out of the area Air outlet grille Air intake grille 20cm or ...

Page 6: ... hose into the pump drain hose outlet for depth of 15mm at least See Fig 11 then lead the water hose to the floor drain or a suitable drainage facility Press the pump pad of the unit to activated the pump operation When the bucket is full the pump starts to work NOTE The pump may cause big noise when it starts to work for 3 5 minutes It is a normal phenomenon Pump drain hose Pump drain hose outlet...

Page 7: ... pump Check the pump hose does not link or block Empty the water of the bucket 3 Clean the air filter Remove the filter every two weeks based on normal operating conditions To remove the filter pull filter outwards See Fig 14 Wash the filter with clean water then dry Re install the filter replace Bucket DO NOT operate the dehumidifier without a filter because dirt and lint will clog it and reduce ...

Page 8: ......

Reviews: