Removing the collected water

1. Pull out the bucket  a little.

2. Hold both sides of the bucket
    with even strength, and pull it
    out from the unit.

3. Pour the water out.

There are three ways to remove collected water.
1. Use the bucket

When the unit is off,if the bucket is full, the Full indicator

     light will light.
     When the unit is on,if the bucket is full, the compressor
     and the fan turn off, and the Full indicator light will light,
     the digital display shows P2.
     Slowly pull out the bucket. Grip the left and right
     handles securely, and carefully pull out straight so
     water does not spill. Do not put the bucket on the floor
     because the bottom of the bucket is uneven. Otherwise
     the bucket will fall and cause the water to spill.
     Throw away the water and replace the bucket. The
     bucket must  be in right place and securely seated  for the
     dehumidifier to operate.
     The machine will re-start when the bucket is restored
     in its correct position.

NOTES:

    When you remove the bucket, do not touch any parts
     inside of the unit. Doing so may damage the product.
     Be sure to push the bucket gently all the way into the
     unit. Banging the bucket against anything or failing to
     push it in securely may cause the unit not to operate.
     If the pump hose drops when you remove the bucket
     (see Fig.7),you must reinstall the pump hose properly
     to the unit before replace the bucket into the unit
     (see Fig.8).
     When you remove the bucket,if there is some water in
     the unit you must dry it.
     When the unit is on, if the bucket is removed, the
     compressor and the fan turn off, then the unit will beep
     8 times and the digital display shows Eb.
     When the unit is off, if the bucket is removed, the unit
     will beep 8 times and the digital display shows Eb.

Fig.5

Fig.6

OPERATING THE UNIT

Fig.9

Removing the collected water

3. Pump draining(on some models)

Water can be automatically emptied into a floor
drain  

by 

attaching

the pump drain out with a pump drain hose
(   od=1/4  , supplied).

or a suitable drainage facility

    Remove the continuous drain hose from the unit and install
    the plastic cover to the continuous drain hose outlet of the
    unit by clockwise rotation.(See Fig.11)

Make sure the hose is secure so there are no leaks.

    Direct the hose toward the drain,making sure that there
    are no kinks that will stop the warter flowing.
    Place the end of the hose into the drain and make sure
    the end of the hose is level or down to let the water flow
    smoothly.Do never let it up.
    Select the desired humidity setting and fan speed on the
    unit for pump draining to start.

    Resert the pump drain hose into the pump drain hose
    outlet for depth of 15mm at least (See Fig.11), then lead
    the water hose to the floor drain or a suitable drainage facility.
    Press the pump pad of the unit to activated the pump
    operation. When the bucket is full the pump starts to work.
    NOTE: The pump may cause big noise when it starts to
                work for 3~5 minutes. It is a normal phenomenon.

Pump drain
hose

Pump drain
hose outlet

NOTE: The pump operation on light blinks at 1Hz when the
pump is operational failure. Please turn off the unit and plug
the power cord out. Check the following things:

    Cleaning the filter of the pump.
    -Remove the bucket from the unit, take down the pump
     and clean the filter of the pump (See Fig.12).

Fig.7

Fig.8

Pump hose
drops

Reinstall pump
hose properly

Fig.10

Filter of the pump

    Check that the pump drain hose does not link or block.

Fig.12

    Empty the water of the bucket.
    Reinstall the pump hose if it drops and reinstall the bucket
    properly. Turn on the unit. If the error repeats, call for service.

OPERATING THE UNIT

NOTE: Do not use this operation when the outdoor temperature
is equal to or less than 0 C (32 F), otherwise water is become
ice that will cause the water hose blocked up and the unit failure.
Make sure to empty the bucket once a week when using
the pump draining feature. When the pump draining feature is
not being used, remove the pump drain hose from the outlet.

O

O

2,Take the pump
drain hose out

1,Press the pump drain
hose outlet in

   Press the pump drain hose outlet in and take the pump drain hose
   out from it (See Fig.13). Make sure do not let the water in the pump
   hose drip to the floor.

Remove the
plastic cover
by couter-clockwise
rotation.

Drain hose

Fig.11

Reinstall the
plastic cover

Fig.13

2. Continuous draining

Water can be automatically emptied into a floor
drain by attaching the unit with a water hose
(Id   

5/16 , not included) with a female threaded

end (ID:M=1  , not included)

Make sure the hose is secure so there are no leaks and

    the end of the hose is level or down to let the water flow
    smoothly.
    Direct the hose toward the drain,making sure that
    there are no kinks that will stop the warter flowing.

    Remove the plastic cover from the back drain outlet of
    the unit and set aside, then insert the drain hose through
    the drain outlet of the unit and lead the drain hose to
    the floor drain or a suitable drainage facility. (See.Fig.9
    and Fig.10)
    When you remove the plastic cover, if there is some
    water in the back drain outlet of the unit you must dry it.

NOTE: When the continuous draining feature is not being used,remove the drain hose from the outlet,
and dry the water in the continuous drain hose outlet.

    Select the desired humidity setting and fan speed on the
    unit for continuous draining to start.

Summary of Contents for PAD60P1AGR

Page 1: ...pecifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Before operating this product please read the instructions carefully and save this manual for future use ...

Page 2: ...erly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all Read This Manual CAUTION This appliance can be used by children aged from 8 years and above...

Page 3: ...Do not cover the intake or exhaust openings with cloths or towels A lack of air flow can lead to overheating and fire Never insert your finger or other foreign objects into grills or openings Take special care to warn children of these dangers Do not use in areas where chemicals are handled This will cause the unit deterioration due to chemicals and solvents dissolved in the air Care should be tak...

Page 4: ...Shows the set humidity level from 35 to 85 or auto start stop time 0 24 while setting then shows the actual 5 accuracy room humidity level in a range of Humidity sensor error Unplug the unit and plug it back in If error repeats call for service 30 RH Relative Humidity to 90 RH Relative Humidity Error Codes and Protection Code AS Auto Shut Off The shuts off when the bucket is full or when the bucke...

Page 5: ...ttom of unit Casters can move freely Do not force casters to move over carpet nor move the unit with water in the bucket The unit may tip over and spill water A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area such as a closet unless there is adequate circulation of air in and out of the area Air outlet grille Air intake grille 20cm or ...

Page 6: ... hose into the pump drain hose outlet for depth of 15mm at least See Fig 11 then lead the water hose to the floor drain or a suitable drainage facility Press the pump pad of the unit to activated the pump operation When the bucket is full the pump starts to work NOTE The pump may cause big noise when it starts to work for 3 5 minutes It is a normal phenomenon Pump drain hose Pump drain hose outlet...

Page 7: ... pump Check the pump hose does not link or block Empty the water of the bucket 3 Clean the air filter Remove the filter every two weeks based on normal operating conditions To remove the filter pull filter outwards See Fig 14 Wash the filter with clean water then dry Re install the filter replace Bucket DO NOT operate the dehumidifier without a filter because dirt and lint will clog it and reduce ...

Page 8: ......

Reviews: