30
For MS11M-24HRDN1-MT0W model:
4¡ã
C(39.2¡ã
F)
T1-Ts
High
Low
Medium
3¡ã
C(37.4¡ã
F)
1.5¡ã
C(34.7¡ã
F)
1.0¡ã
C(33.8¡ã
F)
8.4.3 Heating Mode
8.4.3.1 Compressor running rules
The maximum operation frequency of the
compressor after starting submits to the
following rule.
Fmax=F3
Fmax=F5
Fmax=F7
Fmax=F9
Fmax=F10
Fmax=F8
Fmax=F6
Fmax=F2
34¡ã
C(93.2¡ã
F)
T4
Off
Fmax=F4
33¡ã
C(91.4¡ã
F)
28¡ã
C(82.4¡ã
F)
27¡ã
C(80.6¡ã
F)
25¡ã
C(77.0¡ã
F)
24¡ã
C(75.2¡ã
F)
22¡ã
C(71.6¡ã
F)
21¡ã
C(69.8¡ã
F)
19¡ã
C(66.2¡ã
F)
18¡ã
C(64.4¡ã
F)
17¡ã
C(62.6¡ã
F)
16¡ã
C(60.8¡ã
F)
15¡ã
C(59.0¡ã
F)
14¡ã
C(57.2¡ã
F)
12¡ã
C(53.6¡ã
F)
11¡ã
C(51.8¡ã
F)
6.0¡ã
C(42.8¡ã
F)
5.0¡ã
C(41.0¡ã
F)
Fmax: The maximum operation frequency of
compressor.
F1~F8: The detailed value of the compressor
operation frequency.
If users switch on AC by remote controller, the
compressor will run at the Fmax frequency for 7
minutes according to outdoor ambient temp.
During the 7 minutes, the frequency limitation is
active.
7 minutes later, the compressor running
frequency will be controlled as below:
5.0¡ã
C(41¡ã
F)
4.5¡ã
C(40.1¡ã
F)
T1-Ts-
¦ ¤
T
H
G
F
E
D
C
B
A
3.5¡ã
C(38.3¡ã
F)
3.0¡ã
C(37.4¡ã
F)
2.5¡ã
C(36.5¡ã
F)
2.0¡ã
C(35.6¡ã
F)
1.5¡ã
C(34.7¡ã
F)
1.0¡ã
C(33.8¡ã
F)
0.5¡ã
C(32.9¡ã
F)
While the zones of A,B,C... are corresponding
to different compressor running frequency.
ΔT=0°C(32°F) as default.
Note:
When T1-Ts keeps in the same temp. zone for
3 minutes, the compressor will run as the below
rules:
A~E: Increase the frequency to the higher level
until to F10.
F: Keep the current frequency.
G: Decrease the frequency to the lower level
until to F1.
H: Run at F1 for 1h.(if T1-Ts-
ΔT >6°C(42.8°F),
the compressor will stop)
Meanwhile, the compressor running frequency
is limited by the current.
I3HEAT
I2HEAT
I1HEAT
Off
Decrease
Hold
Resume
I3HEAT, I2HEAT,I1HEAT mean different
running current value.
Off: Compressor stops.
Decrease: Decrease the running frequency to
the lower level.
Hold: Keep the current frequency.
Summary of Contents for Mono 3D
Page 14: ...12 5 Wiring Diagram 5 1 Indoor Unit MS11M 09HRFN1 MW0W MS11M 12HRFN1 MV0W MS11M 18HRFN1 MU0W...
Page 15: ...13 MS11M 24HRDN1 MT0W...
Page 16: ...14 5 2 Outdoor Unit MOC 09HFN1 MW0W MOC 12HFN1 MV0W...
Page 17: ...15 MOF 18HFN1 MU0W...
Page 18: ...16 MOG 24HFN1 MT0W MOC 09HFN1 MW0W MOC 12HFN1 MV0W...
Page 19: ...17 MOF 18HFN1 MU0W...
Page 20: ...18 MOG 24HFN1 MT0W...
Page 29: ...27 T2 7 C 44 6 F the compressor frequency will not be limited...
Page 53: ...51 Take the 9k model as example P U P V...
Page 54: ...52 P W N U...
Page 55: ...53 N V N W...