102
5) Pull out the four wires
of electrical heater (three
orange wires, one grey
wire).
6) Pull out connectors of
the compressor top temp.
sensor, condenser coil
temp. sensor(T3),outdoor
ambient temp. sensor(T4)
and discharge temp.
sensor(T5).
7) Remove the
grounding screw.
Grounding screw
Four temp. sensor connectors