Installation of Outdoor Units
R410A
Tropical Split Type Technical Manual
Installation
128
3.2 Installation Space
•
When installing the unit, leave a space for maintenance shown in the following figure. Install the power
supply at the side of the outdoor unit.
•
Ensure enough space for installation and maintenance. (Fig-14 and Fig-15)
Air outlet
Air inlet
Air inlet
Fig-14
≥
1000 mm
≥
1000 mm
≥
500 mm
≥
1000 mm
≥
1000 mm
Fig-15
NOTE:
1. In case any obstacles exist above the outdoor unit, such obstacles must be 2000mm above the outdoor unit.
2. If miscellaneous articles are piled around the outdoor unit, such articles must be 400mm below the top of the outdoor unit.