background image

Safety 

Precautions

 Page 4


In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.

Your air conditioner should be used in such a way that it is protected from moisture. 

e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can 

fall or be pulled into water or any other liquid. Unplug immediately if it occurs. 

All wiring must be performed strictly in accordance with the wiring diagram located inside of 

the unit.

The unit's circuit board(PCB) is designed with a fuse to provide overcurrent protection. The 

specifications of the fuse are printed on the circuit board, such as: T 3.15A/250V, etc.

When the water drainage function is not in use, keep the upper and the lower drain plug firmly 

to the unit to get rid of choking. When the drain plug is not in use, keep it carefully to prevent

children from choking. 








This appliance can be used by children aged from 8 years and above and person with reduced 

physical, sensory or mental capabilities or lack of experience and knowledge if they have been 

given supervision or instruction concerning use of the appliance in a safe way and understand 

the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance 

shall not be made by children without supervision. (be applicable for the European Countries)

This appliance is not intended for use by persons (including childern) with reduced physical, 

sensory or mental capabilities or lack of experience and knowledge, unless they have been 

given supervision or instruction concerning use of the appliance by a person responsible for 

their safety. Children should be supervised to ensure that they do not play with the appliance. 

Children must be supervised around the unit at all times.(be applicable for other countries 

except the European Countries )

If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or 

similarly qualified persons in order to avoid a hazard.

 CAUTION

Disconnect the power if strange sounds, smell, or smoke comes from it.

Do not press the buttons on the control panel with anything other than your fingers.

Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has 

been dropped or damaged.

Do not operate or stop the unit by inserting or pulling out the power cord plug.

Do not use this product for functions other than those described in this instruction manual.

Before cleaning, turn off the power and unplug the unit.

Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.

Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has 

been dropped or damaged.

Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar 

coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area 

and where it will not be tripped over.

Do not operate unit with a damaged cord, plug, power fuse or circuit breaker. Discard unit or 

return to an authorized service facility for examination and/or repair. 

To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.

The appliance shall be installed in accordance with national wiring regulations.

Contact the authorised service technician for repair or maintenance of this unit.

Contact the authorised installer for installation of this unit.

Do not cover or obstruct the inlet or outlet grilles.

Summary of Contents for 373127

Page 1: ...TIONER Local Air Conditioner Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual fo...

Page 2: ...ecautions Air Filter Cleaning Troubleshooting Tips Unit Cleaning Store the unit when not in use Preparation Design Notice Energy Rating Information Ambient Temperature Range For Unit Operating Exhaust...

Page 3: ...grounded and has the appropriate voltage The power cord is equipped with a three prong grounding plug to protect against shock Voltage information can be found on the nameplate of the unit Your unit...

Page 4: ...ould be supervised to ensure that they do not play with the appliance Children must be supervised around the unit at all times be applicable for other countries except the European Countries If the su...

Page 5: ...Wild disposal of waste in forests and landscapes endangers your health when hazar do us substances leak into the ground water and find their way into the food chain Do not use hazardous chemicals to c...

Page 6: ...e use of flammable refrigerants AVERTISSEMENT Ne pas utiliser de produits permettant d acc l rer le d gel ou de produits de nettoyage autres que ceux recommand s par le fabricant L appareil doit tre e...

Page 7: ...side the package will not cause a leak of the refrigerant charge The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations 3 General work area A...

Page 8: ...uit is being used the secondary circuit shall be checked for the presence of refrigerant Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be cor...

Page 9: ...e following leak detection methods are deemed acceptable for systems containing flammable refrigerants Electronic leak detectors shall be used to detect flammable refrigerants but the sensitivity may...

Page 10: ...Isolate system electrically c Before attempting the procedure ensure that Mechanical handling equipment is available if required for handling refrigerant cylinders All personal protective equipment i...

Page 11: ...y Installation Instructions Preparation NOTE All the illustrations in the manual are for explanation purpose only Your machine may be slightly different The actual shape shall prevail The unit can be...

Page 12: ...this could cause damage to the unit 50cm 19 7 inch 30cm 30cm 12inch 12inch 50cm 19 7inch Energy Rating Information The unit with 3 meters extended exhaust duct is running by using 2 exhaust ducts Diam...

Page 13: ...ving the air feeling damp To find the proper air conditioner determine the square footage of the room you want to cool by multiplying the room length by its width You also need to know the air conditi...

Page 14: ...der A Bolt 1 pc 1 set Unit Adaptor Security Bracket and 2 Screws 1 pc 1 pc Exhaust Hose Drain Hose 1 pc 1 pc Window Slider Adaptor Power Cord Buckle O N O F F T E M P S H O R T C U T T IM E R O N T IM...

Page 15: ...he Adjustable Window Slider or or Window slider A MODEL A MODEL B Window slider B Bolt Window slider A Window slider B Bolt MODEL A MODEL B MODEL C MODEL D 1 2 Window slider A Window slider B Window s...

Page 16: ...m to the window sash and frame as shown 2 Insert the window slider assembly into the window opening Or Foam seal B Adhesive type shorter Foam seal A Adhesive type Foam seal B Adhesive type shorter Foa...

Page 17: ...he wall for the Wall Exhaust Adaptor B 2 Secure the Wall Exhaust Adaptor B to the wall using the four Anchors and Screws provided in the kit 3 Connect the Exhaust Hose Assembly with Wall Exhaust Adapt...

Page 18: ...8 minutes the unit exits Wireless connection mode automatically After Wireless connection is successful you can press and hold SWING and DOWN buttons at the same time for 3 seconds to turn off Wirele...

Page 19: ...the set temperature in C or F F no display for some models and the Auto timer settings While on DRY and FAN modes it shows the room temperature Shows Error codes and protection code E1 Room temperatu...

Page 20: ...Auto off stop program Press or hold the UP or DOWN button to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time re...

Page 21: ...ut drain connector just attach the drain hose to the hole Place the open end of the Hose adaptor directly over the drain area in your basement floor that there are no kinks that will stop the warter f...

Page 22: ...nit with a dry lint free cloth Drain the unit s water collection tray according to the instructions in the following section Run the appliance on FAN mode for 12 hours in a warm room to dry it and pre...

Page 23: ...if possible The unit is noisy and vibrates too much The unit makes a gurgling sound The ground is not level Place the unit on a flat level surface The air filter is blocked with dust or animal hair Tu...

Page 24: ...and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the servi...

Reviews: