Operation Instructions

 Operating

Instructions

and the LED DISPLAY shows 'OF' for 3 seconds, 

press SWING and UP(+) buttons at the same

time to turn on Wireless function and the LED 

DISPLAY shows 'On' for 3 seconds.

NOTE: When you restart the Wireless function, 

it may take a period of time to connect to the 

network automatically.

Timer button
Used to initiate the AUTO ON start  time and 

AUTO OFF stop time program, in conjuction 

with the + & - buttons. The timer on/off 

indicator light illuminates under the timer on/

off settings.

Mode button

Selects the appropriate operating mode. Each 

time you press the button, a mode is selected 

in a sequence that goes from AUTO), COOL, 

DRY, FAN and HEAT (cooling only models 

without). The mode indicator light illuminates 

under the different mode settings.

Up (+) and Down (-) buttons
Used to adjust (increasing/decreasing) 

temperature settings in 1°C/1°F (or 2 °F) increments 

in a range of 17°C/62°F to 30°C/86°F (or 88°F) or the 

TIMER setting in a range of 0~24hrs.

NOTE: The control is capable of displaying 

temperature in degrees Fahrenheit or degrees 

Celsius. To convert from one to the other, press 

and hold the Up and Down buttons at the same 

time for 3 seconds.

Fan/Constant fan(On some models) button
Control the fan speed. Press to select the fan 

speed in four steps-LOW, MED, HIGH and AUTO. 

The fan speed indicator light illuminates under 

different fan settings. When select AUTO fan 

speed, all the fan indicator lights turn dark. On

some models, when select AUTO fan speed, all 

the fan indicator lights illumiante. 

Sleep(Eco) button

Used to initiate the SLEEP/ECO operation.

Power button

Power switch on/off.

LED display

Shows the set temperature in °C or °F("°F" no 

display for some models) and the Auto-timer 

settings.  While on DRY and FAN modes, it 

shows the room temperature.

Shows Error codes and protection code:

E1-Room temperature sensor error.

E2-Evaporator temperature sensor error.

E3-Condenser temperature sensor error 

      (On some models).

E4-Display panel communication error.

EC-Refrigerant leakage detection malfunction

      (On some models).

P1-Bottom tray is full--Connect the drain hose 

and drain the collected water away.If protection 

repeats,call for service.

Note: When one of the above malfunctions 

occurs, turn off the unit, and check for any 

obstructions. Restart the unit, if the malfunction 

is still present, turn off the unit and unplug the 

power cord. Contact the manufacturer or its 

service agents or a similar qualified person for 

service.

COOL operation

·  Press the "MODE" button until the "COOL" indicator 

   light comes on.

·  Press the ADJUST buttons "+" or "-" to select your 

   desired room temperature. The  temperature can be 

   set within a range of 17°C~30°C/62°F~86°F(or 88°F).

·  Press the  "FAN SPEED" button to choose the fan 

   speed.

HEAT operation(cooling only models without)

·  Press the  "MODE" button until the  "HEAT" indicator 

   light comes on. 

·  Press the  ADJUST buttons "+" or " - " to select your 

   desired room temperature. The temperature can be 

   set within a range of 17°C~30°C/62°F~86°F(or 88°F).

·  Press the "FAN SPEED" button to choose the fan 

   speed. 

CONSTANT FAN(Press 3s)

ION/Fresh feature(on some models)

Press FAN button for 3 seconds to initiate ION/FRESH 

feature and 

the ION/FRESH light illumiantes(if applicable), 

the LED DISPLAY shows 'O

n

' for 3 seconds for some 

units

. The ion generatoris energized and will help to 

purify the air inside. Press it for 3 seconds again to 

stop the ION/FRESH 

feature and the ION/FRESH light 

turn dark(if applicable), the LED DISPLAY shows 'OF' 

for 3 seconds for some units.

Summary of Contents for 373127

Page 1: ...TIONER Local Air Conditioner Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual fo...

Page 2: ...ecautions Air Filter Cleaning Troubleshooting Tips Unit Cleaning Store the unit when not in use Preparation Design Notice Energy Rating Information Ambient Temperature Range For Unit Operating Exhaust...

Page 3: ...grounded and has the appropriate voltage The power cord is equipped with a three prong grounding plug to protect against shock Voltage information can be found on the nameplate of the unit Your unit...

Page 4: ...ould be supervised to ensure that they do not play with the appliance Children must be supervised around the unit at all times be applicable for other countries except the European Countries If the su...

Page 5: ...Wild disposal of waste in forests and landscapes endangers your health when hazar do us substances leak into the ground water and find their way into the food chain Do not use hazardous chemicals to c...

Page 6: ...e use of flammable refrigerants AVERTISSEMENT Ne pas utiliser de produits permettant d acc l rer le d gel ou de produits de nettoyage autres que ceux recommand s par le fabricant L appareil doit tre e...

Page 7: ...side the package will not cause a leak of the refrigerant charge The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations 3 General work area A...

Page 8: ...uit is being used the secondary circuit shall be checked for the presence of refrigerant Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be cor...

Page 9: ...e following leak detection methods are deemed acceptable for systems containing flammable refrigerants Electronic leak detectors shall be used to detect flammable refrigerants but the sensitivity may...

Page 10: ...Isolate system electrically c Before attempting the procedure ensure that Mechanical handling equipment is available if required for handling refrigerant cylinders All personal protective equipment i...

Page 11: ...y Installation Instructions Preparation NOTE All the illustrations in the manual are for explanation purpose only Your machine may be slightly different The actual shape shall prevail The unit can be...

Page 12: ...this could cause damage to the unit 50cm 19 7 inch 30cm 30cm 12inch 12inch 50cm 19 7inch Energy Rating Information The unit with 3 meters extended exhaust duct is running by using 2 exhaust ducts Diam...

Page 13: ...ving the air feeling damp To find the proper air conditioner determine the square footage of the room you want to cool by multiplying the room length by its width You also need to know the air conditi...

Page 14: ...der A Bolt 1 pc 1 set Unit Adaptor Security Bracket and 2 Screws 1 pc 1 pc Exhaust Hose Drain Hose 1 pc 1 pc Window Slider Adaptor Power Cord Buckle O N O F F T E M P S H O R T C U T T IM E R O N T IM...

Page 15: ...he Adjustable Window Slider or or Window slider A MODEL A MODEL B Window slider B Bolt Window slider A Window slider B Bolt MODEL A MODEL B MODEL C MODEL D 1 2 Window slider A Window slider B Window s...

Page 16: ...m to the window sash and frame as shown 2 Insert the window slider assembly into the window opening Or Foam seal B Adhesive type shorter Foam seal A Adhesive type Foam seal B Adhesive type shorter Foa...

Page 17: ...he wall for the Wall Exhaust Adaptor B 2 Secure the Wall Exhaust Adaptor B to the wall using the four Anchors and Screws provided in the kit 3 Connect the Exhaust Hose Assembly with Wall Exhaust Adapt...

Page 18: ...8 minutes the unit exits Wireless connection mode automatically After Wireless connection is successful you can press and hold SWING and DOWN buttons at the same time for 3 seconds to turn off Wirele...

Page 19: ...the set temperature in C or F F no display for some models and the Auto timer settings While on DRY and FAN modes it shows the room temperature Shows Error codes and protection code E1 Room temperatu...

Page 20: ...Auto off stop program Press or hold the UP or DOWN button to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time re...

Page 21: ...ut drain connector just attach the drain hose to the hole Place the open end of the Hose adaptor directly over the drain area in your basement floor that there are no kinks that will stop the warter f...

Page 22: ...nit with a dry lint free cloth Drain the unit s water collection tray according to the instructions in the following section Run the appliance on FAN mode for 12 hours in a warm room to dry it and pre...

Page 23: ...if possible The unit is noisy and vibrates too much The unit makes a gurgling sound The ground is not level Place the unit on a flat level surface The air filter is blocked with dust or animal hair Tu...

Page 24: ...and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the servi...

Reviews: