background image

 Page 20

 Operating

Instructions

Other features

Note: For some models, the fan speed can not be 

adjusted under HEAT mode.  

AUTO operation

·  When you set the air conditioner in AUTO mode, it 

   will automatically select cooling, heating(cooling 

   only models without), or fan only operation 

   depending on what temperature you have selected 

   and the room temperature.

·  The air conditioner will control room temperature 

   automatically round the temperature point set by 

   you.

·  Under AUTO mode, you can not select the fan speed.

NOTE: Under AUTO mode, both the AUTO mode and 

the actual operation mode indicator lights illuminate 

for some models.

FAN operation

·  Press the  "MODE" button until the"FAN " indicator 

   light comes on. 

·  Press the "FAN SPEED" button to choose the fan 

   speed. The temperature can not be adjusted.

·  Do not put the duct to window.

DRY operation

·  Press the  "MODE" button until the  "DRY" indicator 

   light comes on.     

·  Under this mode, you cannot select a fan speed or 

   adjust the temperature. The fan  motor operates at  

   LOW speed.

·  Keep windows and doors closed for the best 

   dehumidifying effect.

·  Do not put the duct to window.

TIMER operation

·  When the unit is on, press the Timer button will   

   initiate the Auto-off stop program, the TIMER OFF 

   indicator light illuminates. Press the UP or down 

   button to select the desired time. Press the TIMER 

   button again within 5 seconds, the Auto-on start 

   program is initiated. And the TIMER ON indicator light 

   illuminates. Press the up or down button to select the 

   desired Auto-on start time.

 

 

·  When the unit is off, press the Timer button to initiate 

   the Auto-on start program, press it again within 5 

   seconds will initiate the Auto-off stop program.

·  Press or hold the UP or DOWN button to change the 

   Auto time by 0.5 hour increments, up to 10 hours, 

   then at 1 hour increments up to 24 hours. The 

   control will count down the time remaining until 

   start. 

·  The system will automatically revert back to display 

   the previous temperature setting if there is no 

   operation in a 5 seconds period.

·  Turning the unit ON or OFF at any time or adjusting 

   the timer setting to 0.0 will cancel the Auto Start/

   Stop timer program.

SLEEP(ECO) operation

·  Press this button, the selected temperature will 

   increase(cooling) or decrease(heating) by 1°C/2°F(or 

   1°F) 30 minutes. The temperature will then increase 

   (cooling) or decrease (heating) by another 1°C/2°F(or 

   1°F) after an additional 30 minutes. This new 

   temperature will be maintained for 7 hours before it 

   returns to the originally selected temperature. This 

   ends the Sleep/Eco mode and the unit will continue 

   to operate as originally programmed. 

NOTE: This feature is unavailabe under FAN or DRY 

mode.

 

FOLLOW ME/TEMP SENSING feature(On some models) 

NOTE:This feature can be activated from the remote 

control ONLY. The remote control serves as a remote 

thermostat allowing for the precise temperature 

control at its location. 

To activate the Follow Me/Temp Sensing feature, point 

the remote control towards the unit and press the 

Follow Me/Temp Sensing button. The remote control 

will send this signal to the air conditioner until press 

the Follow Me/Temp Sensing button again. If the unit 

does not receive the Follow Me/Temp Sensing signal

during any 7 minutes interval, the unit will exit the 

Follow Me/Temp Sensing mode. 

NOTE: This feature is unavailabe under FAN or DRY 

mode.

AUTO-RESTART

If the unit breaks off unexpectedly due to the power 

cut, it will restart with the previous function setting 

automatically when the power resumes.

Summary of Contents for 373127

Page 1: ...TIONER Local Air Conditioner Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual fo...

Page 2: ...ecautions Air Filter Cleaning Troubleshooting Tips Unit Cleaning Store the unit when not in use Preparation Design Notice Energy Rating Information Ambient Temperature Range For Unit Operating Exhaust...

Page 3: ...grounded and has the appropriate voltage The power cord is equipped with a three prong grounding plug to protect against shock Voltage information can be found on the nameplate of the unit Your unit...

Page 4: ...ould be supervised to ensure that they do not play with the appliance Children must be supervised around the unit at all times be applicable for other countries except the European Countries If the su...

Page 5: ...Wild disposal of waste in forests and landscapes endangers your health when hazar do us substances leak into the ground water and find their way into the food chain Do not use hazardous chemicals to c...

Page 6: ...e use of flammable refrigerants AVERTISSEMENT Ne pas utiliser de produits permettant d acc l rer le d gel ou de produits de nettoyage autres que ceux recommand s par le fabricant L appareil doit tre e...

Page 7: ...side the package will not cause a leak of the refrigerant charge The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations 3 General work area A...

Page 8: ...uit is being used the secondary circuit shall be checked for the presence of refrigerant Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be cor...

Page 9: ...e following leak detection methods are deemed acceptable for systems containing flammable refrigerants Electronic leak detectors shall be used to detect flammable refrigerants but the sensitivity may...

Page 10: ...Isolate system electrically c Before attempting the procedure ensure that Mechanical handling equipment is available if required for handling refrigerant cylinders All personal protective equipment i...

Page 11: ...y Installation Instructions Preparation NOTE All the illustrations in the manual are for explanation purpose only Your machine may be slightly different The actual shape shall prevail The unit can be...

Page 12: ...this could cause damage to the unit 50cm 19 7 inch 30cm 30cm 12inch 12inch 50cm 19 7inch Energy Rating Information The unit with 3 meters extended exhaust duct is running by using 2 exhaust ducts Diam...

Page 13: ...ving the air feeling damp To find the proper air conditioner determine the square footage of the room you want to cool by multiplying the room length by its width You also need to know the air conditi...

Page 14: ...der A Bolt 1 pc 1 set Unit Adaptor Security Bracket and 2 Screws 1 pc 1 pc Exhaust Hose Drain Hose 1 pc 1 pc Window Slider Adaptor Power Cord Buckle O N O F F T E M P S H O R T C U T T IM E R O N T IM...

Page 15: ...he Adjustable Window Slider or or Window slider A MODEL A MODEL B Window slider B Bolt Window slider A Window slider B Bolt MODEL A MODEL B MODEL C MODEL D 1 2 Window slider A Window slider B Window s...

Page 16: ...m to the window sash and frame as shown 2 Insert the window slider assembly into the window opening Or Foam seal B Adhesive type shorter Foam seal A Adhesive type Foam seal B Adhesive type shorter Foa...

Page 17: ...he wall for the Wall Exhaust Adaptor B 2 Secure the Wall Exhaust Adaptor B to the wall using the four Anchors and Screws provided in the kit 3 Connect the Exhaust Hose Assembly with Wall Exhaust Adapt...

Page 18: ...8 minutes the unit exits Wireless connection mode automatically After Wireless connection is successful you can press and hold SWING and DOWN buttons at the same time for 3 seconds to turn off Wirele...

Page 19: ...the set temperature in C or F F no display for some models and the Auto timer settings While on DRY and FAN modes it shows the room temperature Shows Error codes and protection code E1 Room temperatu...

Page 20: ...Auto off stop program Press or hold the UP or DOWN button to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time re...

Page 21: ...ut drain connector just attach the drain hose to the hole Place the open end of the Hose adaptor directly over the drain area in your basement floor that there are no kinks that will stop the warter f...

Page 22: ...nit with a dry lint free cloth Drain the unit s water collection tray according to the instructions in the following section Run the appliance on FAN mode for 12 hours in a warm room to dry it and pre...

Page 23: ...if possible The unit is noisy and vibrates too much The unit makes a gurgling sound The ground is not level Place the unit on a flat level surface The air filter is blocked with dust or animal hair Tu...

Page 24: ...and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the servi...