INSTALLATION AND OPERATION MANUAL, GAS FLOOR MODEL
BRAISING PAN WITH MANUAL GEARBOX TILT, GS-30, GS-40, GS-40N, GS-60
2.0 INSTALLATION INSTRUCTIONS
UNPACKING
Immediately after unpacking, check for possible shipping damage. If the tilting braising pan is
found to be damaged, save the packaging material and contact the carrier within 15 days of
delivery.
Before installing, verify that the type of gas supply (natural or propane) and electrical service
agree with the specifications on the rating plate located on the left side panel as you face the
front of the braising pan. If the supply and equipment requirements do not agree, contact your
dealer.
LOCATION
The equipment must be kept free and clear of combustible substances. The tilting braising
pan, when installed, must have minimum clearance from combustible and non-combustible
construction of 0" from sides and 6" (152 mm) from the rear. The tilting braising pan is
intended for use on non-combustible floors.
The installation location must allow adequate clearances for servicing and proper operation. A
minimum front clearance of 36" (914 mm) is required.
The tilting braising pan must be installed so that the flow of combustion and ventilation air will
not be obstructed. Adequate clearance for air openings into the combustion chamber must be
provided. Make sure there is an adequate supply of air in the room suitable for the amount of
combustion gas feeding the braising pan burners.
Do not permit fans to blow directly at the tilting braising pan, and wherever possible, avoid open
windows next to the tilting braising pan. Avoid wall-type fans which create air cross currents
within the room.
INSTALLATION CODES AND STANDARDS
Installation must conform with local codes, or in the absence of local codes, with the
National
Fuel Gas Code, ANSI Z223.1/NFPA 54
, or the
Natural Gas and Propane
Installation Code,
CSA B149.1
, as applicable.
1.
The appliance and its individual shut off valve must be disconnected from the gas
supply piping system during any pressure testing of that system at pressures in excess
of ½ psi (3.5 kPa).
MANUAL 10152R4