WARNING
After any conversions, readjustments, or
service work on the oven:
• Perform a gas leak test.
• Test for correct air supply.
• Test for proper combustion and gas supply.
• Check that the ventilation system is in
operation.
WARNING
Keep the appliance area free and clear of
combustibles.
WARNING
The oven must be installed on an even (level)
non-flammable flooring and any adjacent walls
must not be flammable. Recommended
minimum clearances are specified in the
Description section of this manual.
WARNING
Do not obstruct the flow of ventilation air to and
from your oven. There must be no obstruction
around or underneath the oven. Constructional
changes to the area where the oven is installed
shall not affect the air supply to the oven.
CAUTION
To reduce the risk of fire, the appliance is to be
mounted on floors of noncombustible
construction with noncombustible flooring and
surface finish and with no combustible material
against the underside thereof, or on
noncombustible slabs or arches having no
combustible material against the underside
thereof. Such construction shall in all cases
extend not less than 12 inches (304mm) beyond
the equipment on all sides.
NOTICE
For additional installation information, contact your
local Authorized Service Agent.
NOTICE
There must be adequate clearance between the
oven and combustible construction. Clearance must
also be provided for servicing and for proper
operation.
IMPORTANT
An electrical wiring diagram for the oven is located
inside the machinery compartment.
NOTE:
All aspects of the oven installation, including
placement, utility connections, and ventilation
requirements, must conform to any applicable local,
national, or international codes. These codes
supersede the requirements and guidelines provided
in this manual.
NOTE:
In the USA, the oven installation must conform
to local codes. In the absence of local codes, gas oven
installations must conform with the National Fuel Gas
Installation Code, ANSI Z223.1. Gas and electric
ovens, when installed, must be electrically grounded
in accordance with local codes, or in the absence of
local codes, with the National Electrical Code (NEC),
or ANSI/NFPA 70.
NOTE:
In Canada, the oven installation must conform
to local codes. In the absence of local codes, gas oven
installations must conform to the Natural Gas
Installation Code, CAN/CGA-B149.1 or Propane Gas
Installation Code, CAN/CGA-B149.2, as applicable.
Gas and electric ovens, when installed, must be
electrically grounded in accordance with local codes,
or in the absence of local codes, with Canadian
Electrical Code, CSA C22.2.
NOTE:
In Australia, the oven installation must conform
to AS/NZ5601 and carry local Authority or any other
relevant statutory regulations.
Summary of Contents for PS629G Series
Page 10: ...SECTION 1 DESCRIPTION 10 Blank Plates two sizes and an Air Finger...
Page 17: ...SECTION 2 INSTALLATION 17 Model PS629G Dimensions with Optional Legs Casters...
Page 24: ...SECTION 2 INSTALLATION 24 NOTES...
Page 32: ...SECTION 3 OPERATION 32 NOTES...
Page 39: ...SECTION 4 MAINTENANCE 39...
Page 46: ...SECTION 4 MAINTENANCE 46 NOTES...
Page 49: ...SECTION 5 TROUBLESHOOTING 49 NOTES...
Page 50: ......