ADMIN Tab
and email address. If the SMTP gateway is a DNS name, LAN1 on
NETWORK - Ethernet
must
be configured with a valid DNS server address.
Note: When
Clear Now
and
Auto Clear
are used to clear an alarm,
Send Trap
,
Write Log
,
and
Send Email
do not generate notification messages or log entries.
Alarm Descriptions
Note: Alarm indicators for optional features or equipment appear when the related option is
present and enabled.
NTP System Peer Change Alarm:
The SyncServer's current NTP synchronization peer has
changed.
NTP Stratum Change Alarm:
The NTP Stratum level has degraded. For example, the NTP
Stratum has gone from 1 to 2.
NTP Leap Change Alarm:
The SyncServer raises this alarm when the
leap indicator
changes
state. See
STATUS - NTP
(on page 25).
This change of state has two potential causes: The first is that the SyncServer was recon-
figured, causing the NTP daemon to be restarted. More rarely, this can occur when the Syn-
cServer is within 24 hours of a leap second adjustment.
System Network Alarm:
Alarms if a configured port has no connection (network link). Clears if
all configured ports have connections.
System Upgrade Alarm:
The SyncServer checks for software upgrades and raises this alarm if
a software upgrade is available. Microsemi recommends leaving this alarm enabled.
Microsemi recommends enabling
Send Trap
and/or
Send Email
for this alarm on the
ADMIN -
Alarms
page.
Note: In order to detect upgrades, the SyncServer must be correctly configured with a DNS
server and must have http access to the Internet through port 80. This feature is enabled by
default, but can be disabled on the
SYSTEM - General
page.
System Config Change Alarm:
Generates an alarm if the system configuration has been
changed. If the Auto Clear is not selected, this alarm will remain pending until cleared by the
administrator.
System Health Alarm
: The web interface has been unable to automatically save user con-
figuration changes to the backup file. The user might need to perform a manual backup using
the
WIZARDS - Backup
page.
System Up/Down Alarm
: The Syncserver has been restarted.
System Authentication Alarm:
The SyncServer detected a failed login attempt on the web inter-
face.
Timing No Source Alarm
: The Hardware Clock does not have a valid timing reference.
Timing GPS Source Alarm
: (Displayed on GPS-equipped SyncServers only) The GPS time ref-
erence is not providing valid timing information. This may be caused by:
n
An insufficient number of visible GPS satellites.
997-01520-02 Rev. G2
..........................................................................