Installation Guide
See also:
Changes to Passwords and User Names
(see "
Properties of User Names and
Passwords
" on page 20)
Haltingthe SyncServer
Microsemi recommends shutting the operating system down before removing the power.
Using the keypad/display interface:
1. Press the
MENU
button.
2. Select
3) Shutdown
.
3. Select
1) Yes
.
4. Press the
ENTER
button.
5. When the display shows "System Stopped - OK to Turn Power Off Now!" turn the power
off.
Or, using the web interface:
1. Go to the
SERVICES - Startup
page.
2. Select
Halt
and click the
APPLY
button.
3. Wait approximately 30 seconds before removing power.
ConfiguringLAN1
During installation, the user configures LAN1 to gain access to the web interface. After log-
ging in to the web interface, the user can configure the remaining ports on the
NETWORK - Eth-
ernet
page.
The factory default settings for the LAN1 network port are as follows:
n
IP Address:192.168.0.100
n
Mask: 255.255.255.0
n
Gateway: 0.0.0.0
Configure new network settings using the keypad on the front panel:
1. Press the
MENU
button on the front panel.
2. Using the number buttons, select
1) LAN1
, then
1) Config
, and configure the port as
needed.
3. Check the new LAN1 settings by pressing the
STATUS
button repeatedly until "LAN1
STATUS" is shown.
Note: Using the keypad/display interface to configure LAN1, erases the previous settings for
all of the network ports.
Also see MENU Button.