Web Interface
n
Configuring Alarms to clear automatically after 15 minutes.
n
Configuring notification by SNMP traps and email messages.
n
Logging of alarms, notification events.
The
Alarm LED
at the top left corner of the web interface and on the front panel indicates the
highest severity alarm on the
ADMIN - Alarms
page:
n
Red: Alarm with severity =
Major
.
n
Orange: Alarm with severity =
Minor.
n
Green: Alarm with severity =
Notification
, or no alarms.
Alarm Configuration and Notification
Name:
Describes the system event that causes the alarm. Also see
Alarm Descriptions
(on
page 59), and
Alarms and Notification
(on page 116).
State:
A graphic LED indicating the alarm
state
and
severity
at the time the page was gen-
erated:
n
Grey LED: Severity is set to
Notify
.
n
Green LED: Severity is
Major
or
Minor
, and there is no alarm.
n
Orange LED: Severity is set to
Minor
, and there is an alarm.
n
Red LED: Severity is set to
Major
, and the alarm there is an alarm.
Note: To check the current state, click the refresh icon (rotating arrows) at the lower right
corner of the page.
Clear Now:
This checkbox is only available during an alarm. To clear the alarm, select the
Clear Now
checkbox and click the APPLY button. Doing so returns the alarm to a "No
Alarm" state.
Auto Clear:
Automatically clears the alarm after 15 minutes, regardless of the condition that
caused it.
Severity:
Determines the Alarm LED response to an alarm and sets the "Level:" in the SNMP
trap, email message, and log entry.
n
Notify: Does not raise an alarm (No change to Alarm LED color).
n
Minor: Raises a minor system alarm (Alarm LED = Orange).
n
Major: Raises a major system alarm (Alarm LED = Red).
Note: If enabled,
Send Trap
,
Write Log
, and
Send Email
operate in response to alarms,
regardless of Severity.
Send Trap:
Sends an SNMP trap when the alarm occurs and ends. SNMP must be con-
figured correctly on the
NETWORK - SNMP
and
NETWORK – SNMP Traps
pages for this to work.
Write Log:
Generates a log entry in syslog when the alarm occurs and ends. The log can be
viewed from the
LOGS - syslog
page.
Send Email:
Generates a descriptive entry in an email message when the alarm occurs and
ends. The SyncServer compiles the entries over a 5-minute period and sends email mes-
sages at five-minute intervals, so an email alert may contain more than 1 alarm. For Send
Email to work, the
SERVICES - Email
page must be configured with a valid SMTP Gateway
Page 58
..........................................................................
997-01520-02 Rev. G2