Quadrus MINI Imager User’s Manual
10-25
Camera and IP Setup
Fast Linear Mode (FLM) Direction
Auto
The imager tries to read both horizontally and vertically. It decides which direction to process
first based on Window of Interest dimensions. For example, if the WOI height is greater
than its width, the imager attempts to read vertically first, and if there is no decode, then it
attempts to read horizontally.
Horizontal
This setting forces the imager to read horizontally.
Vertical
This setting forces the imager to read vertically.
Definition:
This mode assumes that the whole image is the candidate, and reads the
image either horizontally or vertically. When the number of symbols in the
field of view
<K518>
is set to 2, Fast Linear Mode will try to locate the
candidates first and then decode. The candidate symbols cannot be
side-by-side—they must be parallel.
Usage:
<
K527,
IP Mode,
FLM direction
>
Default:
Auto
Options:
0 = Auto
1 = Horizontal
2 = Vertical
Summary of Contents for Quadrus MINI
Page 1: ...Quadrus MINI Imager User s Manual P N 83 006300 Rev H...
Page 12: ...xii Quadrus MINI Imager User s Manual Statement of RoHS Compliance...
Page 98: ...4 20 Quadrus MINI Imager User s Manual Additional Notes about Calibration...
Page 128: ...5 30 Quadrus MINI Imager User s Manual Setting Up the Imager for EZ Trax...
Page 180: ...6 52 Quadrus MINI Imager User s Manual Background Color...
Page 238: ...7 58 Quadrus MINI Imager User s Manual Configuring EZ Trax Output...
Page 298: ...10 32 Quadrus MINI Imager User s Manual Skew Correction...
Page 318: ...11 20 Quadrus MINI Imager User s Manual Request All Configuration Database Settings...
Page 348: ...13 24 Quadrus MINI Imager User s Manual Other Operational Serial Commands...
Page 362: ...14 14 Quadrus MINI Imager User s Manual Ordered Output Filter...