7-46
Quadrus MINI Imager User’s Manual
Frame Information
Frame Information
Output Frame Number
Disabled
When Output Frame Number is set to Disabled, the frame number is not output as part
of the symbol data.
Enabled
When Output Frame Number is set to Enabled, the number of the frame in which the
symbol was first decoded is attached to the symbol output information. The output format
is “F
nnn
”, where “
nnn
” is a 3-digit decimal value from 0 to 255. The frame number rolls
over to 0 once it passes 255.
If this feature is enabled, the frame information will follow the symbol data, and it will precede
any symbol quality data (if symbol quality settings are enabled—see
Symbol Quality
Separator
on page 8-8). The symbol quality separator is located between the end of the
already-formatted data and the “F” that precedes the frame number.
Output Coordinates
Disabled
When Output Coordinates is set to Disabled, the coordinates are not output as part of
the symbol data.
Enabled
When Output Coordinates is set to Enabled, the four sets of object coordinates for the
first successfully decoded symbol are attached to the symbol data output in the following
format:
“(
nnn,mmm
)”, where “
nnn
” is a 3-digit X-coordinate and “
mmm
” is a 3-digit Y-coordinate.
The validation separator is located between the end of the already formatted data and the
first coordinate point. The point with the lowest X + Y sum will be output first, followed by
the next three points in a clockwise direction.
Example:
(032,040)(287,056)(287,279)(048,271)
Serial Cmd:
<
K734,output frame number
,output coordinates>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Serial Cmd:
<
K734,
output frame number,
output coordinates
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Summary of Contents for Quadrus MINI
Page 1: ...Quadrus MINI Imager User s Manual P N 83 006300 Rev H...
Page 12: ...xii Quadrus MINI Imager User s Manual Statement of RoHS Compliance...
Page 98: ...4 20 Quadrus MINI Imager User s Manual Additional Notes about Calibration...
Page 128: ...5 30 Quadrus MINI Imager User s Manual Setting Up the Imager for EZ Trax...
Page 180: ...6 52 Quadrus MINI Imager User s Manual Background Color...
Page 238: ...7 58 Quadrus MINI Imager User s Manual Configuring EZ Trax Output...
Page 298: ...10 32 Quadrus MINI Imager User s Manual Skew Correction...
Page 318: ...11 20 Quadrus MINI Imager User s Manual Request All Configuration Database Settings...
Page 348: ...13 24 Quadrus MINI Imager User s Manual Other Operational Serial Commands...
Page 362: ...14 14 Quadrus MINI Imager User s Manual Ordered Output Filter...