10-23
Camera and IP Setup
Damaged Symbol
Note: Damaged Symbol is not supported when Q-Mode is enabled.
Usage:
This feature is useful with badly damaged symbols in which finder patterns
or clock patterns are distorted, margins are distorted or missing on one or
both sides of a symbol, or portions of data are damaged.
Definition:
When enabled, the imager will make additional attempts and try different
processes in order to decode the symbol.
Due to the complexity of the algorithm required, enabling this feature
could significantly increase decode time.
Usage:
<
K519,damaged symbol status
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled