Quadrus MINI Imager User’s Manual
7-3
I/O Parameters
I/O Parameters Serial Commands
Power On/Reset Counts
<
K406,
power-on,resets,power-on saves,power-on flash saves
>
Time Since Reset
<
K407,
hours,minutes
>
Service Message
<
K409,
status,service message,threshold,resolution
>
Serial Verification
<
K701,
serial command echo status,serial command beep status,control/hex
output
>
Beeper
<
K702,
status
>
Quality Output
<
K704,
quality output separator,decodes/trigger status
>
Symbol Data Output
<
K705,
symbol data output status,when to output
>
Read Duration Output
<
K706,
status,separator
>
No Read Message
<
K714,
status,message
>
Bad Symbol Message
<
K715,
[unused],message
>
No Symbol Message
<
K716,
[unused],message
>
1D/Stacked Symbology Qualification
<
K717,
minimum number of bars,minimum number of qualified scan
lines,start/stop status
>
2D Symbology Qualification
<
K718,
finder pattern status,symbol size status,symbol size 1,symbol
size 2,symbol size tolerance,dimension status,dimension 1,dimension
2,dimension tolerance,orientation status,orientation value
>
Frame Information
<
K734,
output frame number,output coordinates
>
LED Configuration
<
K737,
LED mode,ISO/IEC 16022 grade
>
Image Output
<
K739,
image output mode,communication port,file format,JPEG quality
>
Target/Flood LEDs
<
K750,
green flash LED status,target pattern LED status,green flash
duration
>
EZ Trax Output
<
K757,
comm port,image mode,image format,JPEG quality,object info
output,grade output
>
Database Identifier Output
<
K759,
status,separator
>
EZ Button
<
K770,
global status,default on power-on,load configuration database,
save for power-on
>
EZ Button Modes
<
K771,
single beep,two beeps,three beeps,four beeps
>
Trend Analysis Output 1
<
K780,
trend analysis mode,trigger evaluation period,number to output on
>
Trend Analysis Output 2
<
K781,
trend analysis mode,trigger evaluation period,number to output on
>
Trend Analysis Output 3
<
K782,
trend analysis mode,trigger evaluation period,number to output on
>
Diagnostic Output 1
<
K790,
unused 1,service unit
>
Diagnostic Output 2
<
K791,
unused 1,service unit
>
Diagnostic Output 3
<
K792,
unused 1,service unit
>
ISO/IEC 16022 Symbol Quality Output 1
<
K800,
output on symbol contrast,symbol contrast threshold,output on
print growth,print growth threshold,output on axial non-uniformity,axial
non-uniformity threshold,output on UEC,UEC threshold
>
ISO/IEC 16022 Symbol Quality Output 2
<
K801,
output on symbol contrast,symbol contrast threshold,output on
print growth,print growth threshold,output on axial non-uniformity,axial
non-uniformity threshold,output on UEC,UEC threshold
>
ISO/IEC 16022 Symbol Quality Output 3
<
K802,
output on symbol contrast,symbol contrast threshold,output on
print growth,print growth threshold,output on axial non-uniformity,axial
non-uniformity threshold,output on UEC,UEC threshold
>
Configurable Output 1
<
K810,
output on,output state,pulse width,output mode
>
Configurable Output 2
<
K811,
output on,output state,pulse width,output mode
>
Configurable Output 3
<
K812,
output on,output state,pulse width,output mode
>
Summary of Contents for Quadrus MINI
Page 1: ...Quadrus MINI Imager User s Manual P N 83 006300 Rev H...
Page 12: ...xii Quadrus MINI Imager User s Manual Statement of RoHS Compliance...
Page 98: ...4 20 Quadrus MINI Imager User s Manual Additional Notes about Calibration...
Page 128: ...5 30 Quadrus MINI Imager User s Manual Setting Up the Imager for EZ Trax...
Page 180: ...6 52 Quadrus MINI Imager User s Manual Background Color...
Page 238: ...7 58 Quadrus MINI Imager User s Manual Configuring EZ Trax Output...
Page 298: ...10 32 Quadrus MINI Imager User s Manual Skew Correction...
Page 318: ...11 20 Quadrus MINI Imager User s Manual Request All Configuration Database Settings...
Page 348: ...13 24 Quadrus MINI Imager User s Manual Other Operational Serial Commands...
Page 362: ...14 14 Quadrus MINI Imager User s Manual Ordered Output Filter...