Panel Functions 149
_________________________________________________________________________________________
_________________________________________________________________________________________
Microplex
logiJET TC8
Edition 1.2
7.33. Configuration of Network Parameters (IP Address, e.g.)
The functions of the submenu Network are used to set the
parameters for connecting the printer to a network (Ethernet).
Setting the IP address manually:
Panel display
[ON LINE ]
[Menu Level 1 ]
[Network ]
[Timeout ]
[Ethernet ]
[Duplex/Speed ]
[IP Assign ]
[Off ]
[Manual ]
[IP Address ]
[192.168.002.002
]
[192.168.010.123
]
[Saved ! ]
Notes
Turn the printer OFF LINE with this key.
Press the NEXT or PREVIOUS key until
[Network ] is displayed.
Press the ENTER key to select the
Network menu.
Press the NEXT or PREVIOUS key until
[Ethernet ] is displayed.
Press the ENTER key to select the
Ethernet menu.
Press the NEXT or PREVIOUS key until
[IP Assign ] is displayed.
Press the ENTER key to select the
IP Assign menu.
The current setting value is displayed.
Press the NEXT or PREVIOUS key until
[Manual ] is displayed.
Press the ENTER key to set the IP
address manually.
Pushing the NEXT or PREVIOUS key
changes the value of the current position
(left digit first, in this example: 1).
Pressing the ENTER key moves you to the
next digit (the ESC key moves you back, if
need be).
The new IP address is saved as setup
value.
Turn the printer ON LINE again: Press
the ON LINE key longer than 2 seconds.