126 Panel Functions
_________________________________________________________________________________________
_________________________________________________________________________________________
Microplex
logiJET TC8
Edition 1.2
7.19. Transparent Code Adjustment
This function configures the transparent code. Using the transparent code
enables you to initiate the commands of the page description language
IDOL by printable characters. The transparent code pre-setting is 2625.
These are the ASCII character codes (hexadecimal) for the characters
&
%
(ref. IDOL Programming Manual)
.
Panel display
[ON LINE ]
[Menu Level 1
]
[Configuration
]
[Interface
]
[Transparent Code
]
[Digit4 2625]
[Digit1 2626]
[Save as Setup? ]
Notes
Turn the printer OFF LINE with this key.
Press the NEXT or PREVIOUS key until
[Configuration ] is displayed.
Press the NEXT or PREVIOUS key until
[Transparent Code ] is displayed.
The hexadecimal number for
&
%
is preset.
Pressing the NEXT or PREVIOUS key
changes the value of the current position
(Digit 4 = left position, in this example: 2).
Pressing the ENTER key moves you to the
next digit (the ESC key moves you back, if
need be).
2626 is selected as transparent code.
From now on use the characters
&
&
before programming the IDOL commands.
In addition this new value can be saved as
setup value (using the ENTER key).
After this decision turn the printer ON LINE
again: Press the ON LINE key longer than 2
seconds.