© Microhard Systems Inc.
CONFIDENTIAL
13
IP9xx Series
2.0 Quick Start
This QUICK START guide will enable you to promptly establish basic
IP connectivity between a pair of IP Series in a point-to-point (ref.
5.1) configuration.
Note that the units arrive from the factory with a Radio Configuration
of ‗Remote‘ and the Local Network setting configured as ‗Static‘ (IP
Address 192.168.1.254, Subnet Mask 255.255.255.0, and Gateway
192.168.1.1).
2.1 Factory Default/Reset Method
2.11 Required Materials
2 IP Series (with (or set to) factory default configura
tion), each with Power Adapter and Rubber Ducky
Antenna
1
PC with NIC (ethernet) card
1
Crossover patchcable (ethernet)*
*dependent on desired test set-up
2.12 Set-Up Procedure
Connect a Rubber Ducky antenna to each IP Series.
Connect the Power Adapters to available 120VAC out-
lets, and to the IP Series. The SYS LED will blink for
approximately 1 minute while it readies itself for opera-
tion.
Using CROSSOVER ethernet patchcable, connect PC
NIC card to rear ETHERNET connection on IP Series.
(PC must have its Network Settings (TCP/IP Properties)
set to STATIC with an IP Address of (e.g.) 192.168.1.10
and a Subnet Mask of 255.255.255.0.)
Open a Web Browser and enter the IP Address
(192.168.1.254) of the IP Series into the URL address
line.
Refer to Section 6.1.1 re LogOn.
continued...
Use the MHS-supplied power
adapter or an equivalent power
source.
To ensure that the IP Series unit is
at its DEFAULT factory settings,
once it has powered-up and the
SYS LED is ON (after 1 minute),
press and hold the front CFG
button for 8 seconds - the SYS
LED will initially blink, then be on
solid, and then the unit will reset.
Note:
Some
OEM customers will
have
their
specific factory defaults
loaded.
Summary of Contents for IP-921
Page 165: ... Microhard Systems Inc CONFIDENTIAL 165 IP9xx Series Appendix B Upgrade Process DOS Prompt ...
Page 166: ... Microhard Systems Inc CONFIDENTIAL 166 IP9xx Series Appendix B Upgrade Procedure DOS Prompt ...
Page 169: ... Microhard Systems Inc CONFIDENTIAL 169 IP9xx Series Appendix E Mounting Dimensions ...