Options Definitions continued…
Chime
Both the internal and external chime activate at the same time.
3.1 Internal Chime Duration
Sets whether the internal chime sounds: none, once, or twice. The display comes standard with the internal chime.
3.2 External Chime Duration
Sets the duration of the external chime. This is actually an external "chime driver" circuit that may be purchased at
the time of order. For AC loads (such as a doorbell), the triac option is recommended. For DC loads, the relay option
is recommended.
3.3 Chime Volume [Internal Chime]
Sets the volume of the internal chime.
Display
4.1 STU Range Lock
Sets the smallest time unit that will be shown by the display, e.g., to have a 4-digit display show hours and minutes
(never seconds), set this value to "2."
4.2 LTU Range Lock
Sets the largest time unit that will be shown by the display, e.g., to have a 4-digit display show hours and minutes
(never seconds), set this value to "3."
4.3 Leading Zeros
Shows or hides the leading zeros for timers. Unit Counter and Takt time modes always suppress the leading zeroes.
4.4 Colon Flash Rate
Determines how fast the colons flash while the timer is running.
4.5 Size
This is the display's factory set number of digits. A four-digit display is indicated by a "4." This option lets the display
know how much information it can show on the screen. Note: Some input prompts can only display all of the
information on a 6-digit display. Smaller displays will show only the right hand portion of the prompt.
Events
5.1 On Rollover
Determines what to do when the count up time / interval (2.1.1) overflows.
Time rollover point occurs when the LTU (4.2) time unit overflows.
Interval rollover occurs at 65535 Days, 999999 Hours, Minutes, Seconds, Hundredths of a Second.
•
5.1.0 Stop
Displays the last valid time or interval before the rollover.
•
5.1.1 Continue
Resets to zero and continues counting up.
5.2 On Zero
Determines what to do when the count down time / interval (2.1.2) reaches zero.
•
5.2.0 Stop
Stays at zero
•
5.2.1 Reload & Stop
Load the default countdown time