Microframe Corporation
16
604 South 12
th
Street
Broken Arrow, OK 74012
800-635-3811
www.microframecorp.com
Series 6300XXX8
Options Definitions continued…
Setup continued…
1.6 Quicksets
These allow quick access to commonly used settings. For proper operation, options 1.6.1, 1.6.2, and 1.6.3 require the
date and time to be set before selecting them.
•
1.6.0 Wall Clock
Shows the current time of day
Sets all other options needed to make sure time is displayed as expected: HH:MM:SS or HH:MM.
•
1.6.1 Days Accident Free - Count Up
Counts up the days that have been accident-free. First, set the date and time. Next, select this option. You
will be prompted for the current day, press [ENTER]. The day count will advance at midnight automatically.
•
1.6.2 Days Countdown
Counts down by days.
First, set the date and time. Next, select this option. You will be prompted for the current day, press
[ENTER]. The day count will decrement at midnight automatically.
•
1.6.3 Countdown Time to New Year's Day
Counts down the time until New Year's Day.
First, set the date and time.
Important
: Do not use daylight savings when setting the time or the count will
be off by 1 hour. Next, select this option. The display will begin counting down the time remaining until the
New Year in the format "DDDD.HH: MM:SS". Note that slave displays can be used to show the portion of
the time that does not fit on the master display.
•
1.6.4 Count Up Time from 0:00
Sets a timer to start counting up from zero.
•
1.6.5 Countdown Time 1 hour
Sets a timer to start counting down from 1 hour.
•
1.6.6 Countdown Interval 90 minutes
Sets a timer to countdown 90 by minute intervals.
•
1.6.7 Unit Counter
Sets a unit counter so that input pulses can be counted from Input 1 or Input 2.
•
1.6.8 Takt Timer - 15-second interval
Sets a Takt timer such that every 15 seconds the display will increment by 1 unit. Press the [DOWN] button
to start the timer.
•
1.6.9 Reset Onboard Clock
The internal RTC can be reset. Resets the date, time, and timers. Note: This will impact the display's
current operation.
1.7 Photocell calibration
Allows the user to adjust the photocell offset, so that side-by-side displays are the same brightness.
Calibration steps:
•
Select an indoor room with lighting of average brightness. The calibration does not work well in a dark room
or in full sunlight.
•
Plug in displays side-by-side.
•
Enter this option (Menu 17 Enter). The raw photocell reading is displayed. Subtract the lower number from
the higher one. This will be our offset. Write this down.
•
Unplug the display(s) that will not be changed.
•
Press [ENTER] to continue, or [EXIT] to quit. The current offset is displayed (default 40). Add the offset to
the number displayed, type it in with the remote, and press [ENTER]. e.g. if you wrote down "12" in the last
step, you will type in "52" [ENTER].
•
Display brightness should now match. If not, repeat steps above, using a different offset.