1.1 DESK MOUNTED UNITS

Fit the right angle antenna to the BNC

connector at the rear of the unit. Twist the

collar clockwise until it locks into place. Ensure

the antenna is in the upright position. (see

diagram 2, page 8).

Fit the power connector into the socket

provided at the rear of the unit. Ensure this is

pushed in as far as it will go. Plug in the DC

power adapter to a suitable 110V AC wall outlet.

Check the location of the DataTrack unit,

observing the recommendations detailed on

page 8.

1.2 WALL MOUNTED UNITS

Identify a suitable location for fixing the unit,

observing the recommendations detailed on page

8.

1  INSTALLATION PROCEDURES

Ensure that a minimum of 8 inches beneath

the intended location is left clear for the an-

tenna, and check that the power cable, when

fitted, is within reach of a wall outlet.

Using the bracket provided as a template,

mark out the position of the three holes. Check

that the bracket is vertical prior to fixing. Drill

and fix the bracket to the wall using suitable

wall plugs and fixing screws.

Lift up the DataTrack unit and slide down

onto the bracket, checking that the lugs on the

bracket fit either side of the lip on the DataTrack

base.

Fit M3 screw to the base of the unit and

tighten until the bracket is locked in place.

Check that the unit is secure, then fit the

antenna and power connector (as in Diagrams

1 & 2 “Desk Mount Units” above). The power

cable should be adequately clamped to the wall

to prevent accidental removal.

Diagram 1: Wall Mounting the DataTrack Unit

Summary of Contents for 3061 Series

Page 1: ...Microframe Corporation Series 3061 DataTrack Waiter Call Operating Manual B3061 7013 B3061 7013 ...

Page 2: ...TER INSTALLATION SPECIFICATIONGUIDE ITEM NO A3061 7013 REVISION DATE 08 05 Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Page 3: ...amecorp com Safety Do not install substitute parts or perform any modification to the product without first contacting Microframe Warning Allpowertransformers linecords andelec tricalequipmentshouldbekeptoutofthereach of children and away from water Life Support Policy Microframe s products are not autho rized for use as components in life sup port devices or systems without the ex press written a...

Page 4: ... 9 2 5 TURNING OFF ALL PAGERS 9 3 SYSTEM OVERVIEW 10 3 1 DESCRIPTION 10 3 2 RANGE EXPANSION 10 3 3 IMPORTANTINFORMATION 10 3 4 SAFETY INFORMATION 10 3 5 CARING FOR YOUR TRANSMITTER 10 3 6LIABILITY 10 3 7 WARRANTY INVALIDATION 10 3 8 SERVICE INFORMATION 11 4 POCKET PAGER USER GUIDE 12 4 1 TURNING ON THE PAGER 12 4 2 RECEIVINGAPAGE 12 4 3 MANUAL PAGER TURN OFF 12 4 4 POWER CHECKING 12 4 5 LIGHTING F...

Page 5: ...tterfeaturesindividualcallbut tonsthatcantransmittoanyof14on sitepagers When a call button is pressed a red light will appear in the cornerofthebuttonpressedtoconfirmapagewassent Available for desktop or wall mounting Operation TheDataTrackOne TouchPagingSystemisdesigned to page wait staff with the simple press of a button Names of servers may be written in the white boxes providedusingwaxpencils ...

Page 6: ...OCEDURES Ensure that a minimum of 8 inches beneath the intended location is left clear for the an tenna and check that the power cable when fitted is within reach of a wall outlet Using the bracket provided as a template mark out the position of the three holes Check that the bracket is vertical prior to fixing Drill and fix the bracket to the wall using suitable wall plugs and fixing screws Lift ...

Page 7: ...stem will be affected by the type of material the unit is mounted on and its sur roundings C The following is a list of materials that this transmitter will be adversely affected by if placed in close proximity to a Foil backed wallboard b Metal mesh or wire reinforced glass c Metal sheeting large mirrors or suspended ceilings d Elevator shafts All of the above can reflect radio waves and therebyr...

Page 8: ...s thelightwillflashforapproximately15seconds before extinguishing automatically This helps to prevent the Server from being repeatedly called unnecessarily When the pager receives the call it will vibrate for a short burst and display the mes sage 1 to indicate a standard call 2 3 THE 2x AND 3x BUTTONS The 2x and 3x keys are programmable for predefinedalphamessagesatthetimeoforder but is limited t...

Page 9: ...ratesafely when installed and used according to general safety practices The following requirements should be observed at all times Do NOT subject this equipment to Mechanical shock Excessivehumidityormoisture Extremes of temperature Corrosiveliquids This equipment is designed for indoor use unless expressly stated otherwise and must not be used in classified Hazardous Areas including areas contai...

Page 10: ...ON four times Thewords PGROFF willappearonthe LCD screen Press the LARGE GRAY BUT TON once to confirm NOTE If you have chosen to disable the pagers on off button the pagers can only be turned off from the transmit ter 4 4 POWER CHECKING When the battery level is low a low battery symbol will appear at the bottom of the pager screen 4 5 LIGHTING FUNCTION Pressingthe UPARROWBUTTON forone second can ...

Page 11: ...owardtheground Avoid mounting the dipole on or near to any metal girders pillars or other metallic obstructions The dipole should preferably be mounted at a height which avoids potential snagging with any moveable objects that might be used in the vicinity i e ladders Ensure that the bracket is firmly bolted to a solid surface and that the feeder cable is adequately clamped along its entire run be...

Page 12: ...ing for the waiter num ber to be specified The waiter has not made it backtoacknowledgethepage The transmitter takes a little over a second to send a page and then reset The2Xand3Xbuttonsarevery sensitivetotimingandmustbe pressed at exactly the same time CheckthattheDCpoweradapterisconnected tounit Verifythatoutlettransformerisplugged in to has power Call for tech support Press a waiter number or ...

Page 13: ...poration Series 3061 DataTrack Waiter Call 14 Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Reviews: