Microframe Corporation
Series 3061 - DataTrack Waiter Call
7
1.1 DESK MOUNTED UNITS
Fit the right angle antenna to the BNC
connector at the rear of the unit. Twist the
collar clockwise until it locks into place. Ensure
the antenna is in the upright position. (see
diagram 2, page 8).
Fit the power connector into the socket
provided at the rear of the unit. Ensure this is
pushed in as far as it will go. Plug in the DC
power adapter to a suitable 110V AC wall outlet.
Check the location of the DataTrack unit,
observing the recommendations detailed on
page 8.
1.2 WALL MOUNTED UNITS
Identify a suitable location for fixing the unit,
observing the recommendations detailed on page
8.
1 INSTALLATION PROCEDURES
Ensure that a minimum of 8 inches beneath
the intended location is left clear for the an-
tenna, and check that the power cable, when
fitted, is within reach of a wall outlet.
Using the bracket provided as a template,
mark out the position of the three holes. Check
that the bracket is vertical prior to fixing. Drill
and fix the bracket to the wall using suitable
wall plugs and fixing screws.
Lift up the DataTrack unit and slide down
onto the bracket, checking that the lugs on the
bracket fit either side of the lip on the DataTrack
base.
Fit M3 screw to the base of the unit and
tighten until the bracket is locked in place.
Check that the unit is secure, then fit the
antenna and power connector (as in Diagrams
1 & 2 “Desk Mount Units” above). The power
cable should be adequately clamped to the wall
to prevent accidental removal.
Diagram 1: Wall Mounting the DataTrack Unit