TYPE #4: (CONTINUED)
TYPE# 5: FORD PROBE (+)SINGLE WIRE SYSTEM
-The Ford Probe Uses A Single Wire (+)12 Volt Positive Door Lock System. This Singe Vehicle Wire Controls BOTH
LOCK & UNLOCK. This Means That Both The Unit’s LOCK and UNLOCK Pulse Wires Have To Be Connected To The
SAME Vehicle Wire.
- The (+)12 Volt Positive LOCK Command Is Simply A R)12 Volt Positive Pulse.
- The (+)12 Volt Positive UNLOCK Pulse Command Must Be Resisted Through A 4.7K OHM Resistor.
-The Single Lock/Unlock Wire Is Found In The Kick Panels And Is Green/Black.
ALARM
BLUE(UNLOCK) (-)
GREEN
(LOCK)
(-)
CUT
87
87A
85
86
30
(+) CONSTANT 12 VOLTS
USE 3.5 AMP FUSE
87
87A
85
86
30
(+) CONSTANT 12 VOLTS
USE 3.5 AMP FUSE
GROUND
CONSTANT (+) 12 VOLTS
FUSE EACH AT 10 AMPS
(+)
COMPRESSOR
COMPRESSOR WIRE
SWITCH
VACUUM OPERATE SYSTEM
ALARM
BLUE(UNLOCK)
GREEN
(LOCK)
87
87A
85
86
30
(+) CONSTANT 12 VOLTS
USE 3.5 AMP FUSE
GREEN/BLACK VEHICLE WIRE
87
87A
FUSE
85
86
30
10
FUSE
10
(+) CONSTANT 12 VOLTS
USE 3.5 AMP FUSE
4.7K OHM
RESISTOR
CONSTANT (+) 12 VOLTS
FUSE EACH AT 10 AMPS
(+)
CONSTANT (+) 12 VOLTS
FUSE EACH AT 10 AMPS
(+)
FORD PROBE (+) SINGLE WIRE SYSTEM
TYPE# 6: CHRYSLER SINGLE WIRE SYSTEM
-This Is A Single Wire System. This Singe Vehicle Wire Controls BOTH LOCK & UNLOCK. This Means That Both The
Unit’s LOCK And UNLOCK Pulse Wires Have To Be Connected To The SAME Vehicle Wire.
-Models Such As The 1995 Cirrus/Dodge Stratus Use This System.
-Other Chrysler Models Such As The 1993-95 New Yorker, Concorde, LHS, Dodge Intrepid, & Eagle Vision Can Be Wired
Using This Single Wire Method Or As A 3-Wire (+)Positive Trigger Type. (Since The Factory Door Locking Relays Are
Difficult To Access, The Single Wire Method Is Much Faster)
NOTE:
For Dodge Caravan, Chrysler Town & Country, & Plymouth Voager SEE TYPE #7: SINGLE WIRE SYSTEM.
- This Single Wire System Is Basically A RESISTED (+)12 Volt Positive Trigger System. The Lock Command Is A 3 Volt
Pulse And The UNLOCK Command Is A 6 Volt Pulse. Resistors Can Be Used To Convert The Unit’s Regular (+)12 Volt
Positive Pulse To Operate This System.
- A (+)12 Volt Positive LOCK Pulse Needs To Be Resisted Through A 620 OHM Resistor.
- A (+)12 Volt Positive UNLOCK Pulse Needs To Be Resisted Through A 2.7K OHM Resistor.