background image

Electrical Installation

This  section  explains  how  to  connect  your  FlowTrak  II  to  a 

12-volt power source.

NOTE: The FlowTrak II must be connected to a 12-volt DC 

negative ground electrical system.  

 

Route  the  power  cable  of  the  FlowTrak  II  harness  from  the 

console to the switched source, plug the connector into the 

mating plug for the console and connect the red wire to the 

switched  power  source  as  shown  in 

Illustration 3

  (terminal 

Illustration 3

10

Installation

Mounting the Display Console

Select  a  mounting  location  which  seems  most  workable, 

and  that  best  fits  your  needs.  It  should  be  con ve nient  to 

reach and high ly vis i ble to the op er a tor. DO NOT IN STALL IN 

A  POSITION  THAT  OB STRUCTS  THE  VIEW  OF  THE  ROAD  OR 

WORK AREA. Whenever pos si ble, avoid lo ca tions that ex pose 

the  con sole  to  direct  sun light,  high  tem per a ture,  strong 

chem i cals or rain.

Place the mounting bracket in selected lo ca tion, mark holes, 

drill  1/4”  (7mm)  holes  and  mount  bracket  with  bolts,  lock- 

wash ers  and  nuts  pro vid ed.  (Use  self-tap ping  screws  if  not 

prac ti cal to use bolts.) 

See Illustration 1.

Illustration 1

Illustration 2

Put  rubber  washers  on  carriage  bolts  and  put  the  bolts 

through  the  bracket  holes  from  the  inside  out.  Loosely 

attach the mount knobs onto the bolts. Place console over 

carriage bolt heads and tighten knobs to se cure the console.              

See Il lus tra tion 2.

or wire).  Connect the black wire to a screw or bolt on the 

equipment frame.  Use your test light to locate a terminal or 

wire connected to your ignition switch which is “hot” when 

the ig ni tion is turned on and “dead” when the ignition is off.
Your  FlowTrak  II  is  equipped  with  a  non-volatile  memory 

which does not require a constant supply of power to retain 

daily  totals  or  calibration  values.    This  type  of  memory 

conserves battery power and will not discharge the vehicle’s 

battery when equipment is not in use.  

Drill ¼” (7mm)

holes for bolts,

or 3/16“ (5mm)

holes for self-

tapping screws.

Bolts

Lockwashers

and nuts

Rubber washer

Carriage bolts

Mount knob

CONSOLE END VIEW

Console easily adjusts for

side or dashboard mounting.

Carefully route power

cable to a 12VDC source

Attach RED wire to

terminal or lead that is

“hot” with ignition on.

4-amp in-line fuse (Not Provided) required for unprotected circuits

FUSEHOLDER

Attach Black

Wire (GND) to

Equipment Frame

Summary of Contents for FLOWTRAK II

Page 1: ...Application Monitor Reference M a n u a l...

Page 2: ...urself with this manual and the actual components before beginning Following the procedures described in this manual will ensure proper per for mance and help avoid problems or questions once you are...

Page 3: ...tend the term of the foregoing warranty period should the Buyer return completed warranty registration information with dated proof of purchase to the Seller within one 1 year from the original date o...

Page 4: ...PS 20 Factory loaded Calibration Values 20 Determining Speed Calibration 21 Drive Shaft Speed Sensor Calibration 21 Fine Tuning Speed Distance Cal Value 22 23 Entering Target Test Speed 23 Exiting Cal...

Page 5: ...monitors and displays WIDTH CAL FLOW CAL MIN FLOW TARGET RATE SPEED CAL TEST SPEED VOLUME MINUTE DISTANCE AREA HOUR VOLUME 1 2 3 RATE SPEED AREA 1 2 3 TANK CAL RESET CALHOLD 1 2 3 4 5 II TANK VOL TAN...

Page 6: ...nsor Cable with threaded sensor P N 13096 FM750 GFN Flowmeter P N 11501 Power Speed Flow RH Opt Harness P N 17194 2 2 2 2 2 2 2 C 15 3 Pin Extension Cable M P 150 P N 13207 B 14 Nylon cable ties 10 P...

Page 7: ...ension Cable M P 150 P N 13206 14 Nylon cable ties 5 P N 10045 5 Run Hold Sensor Cable P N 13226 Hardware Bag P N 13251 Speed Sensor Mounting Bracket P N 10013 Magnets 6 2 in hardware bag P N 10012 Va...

Page 8: ...8 FlowTrak II System Overview BLACK TIE SPEED FLOW VES RUN HOLD GREEN TIE YELLOW TIE GRAY TIE OPTIONAL CONTROL GND RED BLACK...

Page 9: ...WHT 20 GA BLK A B C D E F G H J K A B C D E F G H J K P N 17194 10 PIN METRI PACK TOWER 10 PIN METRI PACK 150 SHROUD 18 GA RED 18 GA RED 18 GA WHT 18 GA RED 18 GA BLK 18 GA WHT 18 GA RED 18 GA BLK 18...

Page 10: ...use bolts See Illustration 1 Illustration 1 Illustration 2 Put rubber washers on carriage bolts and put the bolts through the bracket holes from the inside out Loosely attach the mount knobs onto the...

Page 11: ...from wheel slip 2 Tractor vehicle or planter drive shaft This type of mounting is recommended for trucks four wheel drive tractors or other equipment that has poor or no access to a non driven wheel L...

Page 12: ...T SENSOR SENSOR BODY COLOR MAIN HARNESS TIE COLOR Speed Green Yellow Flow Green Green Run Hold Black Gray Vansco Radar Speed Sensor Speed Sensor Options In addition to the standard Hall effect magneti...

Page 13: ...llustration 6 Installing Flow Sensor Cable With the flowmeter in place install the flow sensor cable The flow sensor cable has a GREEN sensor body and mates with the 3 pin connector on the main harnes...

Page 14: ...he sensor When the mag net is away from the sen sor the con sole will be in HOLD and the area and distance counting functions will be disabled NOTE The run hold kit includes a 5 sensor cable and 10 ex...

Page 15: ...ONNECTION USER SUPPLIED RELAY CONTROL 12VDC NOMINAL MOTOR OR SOLENOID RELAY ORVALVE NOT SUPPLIED COIL 5 AMP MAX BLACK RED 2 PIN M P EXT CABLE GND VES YELLOWTIE GREENTIE RUN HOLD BLACKTIE GRAYTIE RED B...

Page 16: ...le in a cool dry location if it will not be used for an extended period of time such as during the off season As with any electronic equipment use care in cleaning so that water or other liquids do no...

Page 17: ...hour WIDTH CAL Used in calibration mode to enter the working width of your sprayer booms or other equipment SPEED Displays ground speed in miles per hour kilometers per hour SPEED CAL Used in calibra...

Page 18: ...d is displayed release the two keys To lock in English mode you must enter and exit cal i bra tion You must be in HOLD to enter Cal Press and hold the CAL key until CAL lights on the display The conso...

Page 19: ...ow Note this feature is inoperative if the system is set up in the Tank FILL mode See Special Calibration pages 25 26 and Tank fill Operation page 30 for setup and operation details for the Tank FILL...

Page 20: ...GPS Speed Astro II 5 189 48 46 56 SkyTrak 910 2 31 9 82 SkyTrak 1 50 38 58 94 Dickey john 210 53 42 00 John Deere In cab speed signal 197 50 44 70 Factory Loaded Calibration Values Calibration Factor...

Page 21: ...de the measured revolution by the number of magnets installed to get your starting SPEED CAL calibration value Once calibration of the system is complete this number should be fine tuned for optimum a...

Page 22: ...ect HOLD mode when the marker on the vehicle passes the ending flag to stop the distance counting function The console display should read HOLD See Illustration to the right Stop the vehicle in a leve...

Page 23: ...in gallons per minute li ters per minute based on the nozzles being used for the en tire boom on the sprayer DO NOT enter the actual flow of your spray application For example If the min i mum flow ra...

Page 24: ...still in the VOLUME position and in HOLD enter calibration boom switches OFF hold the CAL button until red warning light comes on about one second The dis play will show the flowmeter calibration valu...

Page 25: ...are the same as English units except Area is in thousands of square feet Use the and buttons to choose between EnG American English Units MEt Metric and TurF Turf units WIDTH CAL AREA 1 2 3 Material U...

Page 26: ...Turn rotary dial to display desired readout WIDTH CAL FLOW CAL MIN FLOW TARGET RATE SPEED CAL TEST SPEED VOLUME MINUTE DISTANCE AREA HOUR VOLUME 1 2 3 RATE SPEED AREA 1 2 3 TANK CAL RESET MAN 1 2 3 I...

Page 27: ...turn on When the amount pumped into the tank reaches the calibrated TANK VOLUME the Control Output automatically shuts off The display will show FULL and the HOLD icon If the RUN HOLD button is presse...

Page 28: ...if held for 2 seconds If the button is accidentally pressed the console will display CLEAr to alert the user that the counters will be cleared If the user continues to hold the button for 2 seconds CL...

Page 29: ...AREA counter and the 3 VOLUME counter whether the rotary switch is in the AREA or the VOLUME position If the button is released before 2 seconds have elapsed the counters will not be cleared and the C...

Page 30: ...y switch in any position FILL will ash if tank level is equal to or less than tank set point Fill tank and reset TANK counter by setting the rotary switch at the TANK position and pressing the button...

Page 31: ...READOUT OF GALLONS LITERS OR GALLONS LITERS PER MINUTE Check to see that the sprayer pump and equipment are operating properly If liquid is moving through the line check the flow sensor to be sure it...

Page 32: ...e jumper wire connect the ohmmeter to the pins of the dust cover with the jumper wire There should be continuity near zero ohms Troubleshooting cont Checking Individual Components 32 MAGNETIC HALL EFF...

Page 33: ...let of the main harness remote run hold cable grey tie Placing a clip lead or other jumper wire such as a paper clip bent in a U betweenpinsA blue andC violet ofthemainharness run hold connector grey...

Page 34: ...oo small Too much agitation Throttle range adjust or pressure relief valves Larger hoses Reduce agitation Adjust Pressure Speed and Spray Rate don t check out according to charts Inaccurate pressure r...

Page 35: ...d in other areas decrease to 15 GPA After checking the tip charts we find that a TK 5 Floodjet has a range of 14 9 to 30 GPA at 5 MPH According to the charts to get 30 GPA at 5 MPH with a TK 5 the pre...

Page 36: ...Appendices 36...

Page 37: ...3 8 locking nuts See Illustration below ATV Wheels Two mounting examples are illustrated 1 Using one cable tie ribbed side toward magnets secure two magnets to the wheel hub so they are exactly oppos...

Page 38: ...he SOUTH pole side of the magnet Transmission Transfer Case Drive Shaft Magnets Positioned 180 Apart to 6mm to 13mm Spacing Sensor Body Green Fasten Sensor Bracket with Existing Transmission Bolts or...

Page 39: ...ould spin freely If it does not spin freely remove the turbine wipe the shaft and try again If is still does not spin freely the shaft or bearings may have excessive wear Service may be necessary ASSE...

Page 40: ...Ground Common B A DICKEY johnRadarFordConnector DICKEY johnRadarCannonConnector DICKEY johnRadarAmpConnector In CabJohnDeereMetri PackConnector 8000 9000Series RavenRadarConxallConnector Magnavox Phil...

Page 41: ...eters 3 28 feet meters 1 09 yards kilometers 62 miles LAND MEASUREMENT square millimeters 0 00155 square inches square meters 10 764 square feet square meters 1 195 square yards hectares 2 47 acres sq...

Page 42: ...foot remote run hold sensor cable 01531 Speed sensor kit 01535 Remote run hold sensor kit 11501 FM750 GFN Flowmeter 10131 FN750 SS Flowmeter 17194 Power speed flow run hold option harness 10899 FM750N...

Page 43: ......

Page 44: ...i n U S A b y 111 East LeRay Ave Box 99 Eagle Lake MN 56024 0099 Toll Free 800 328 9613 507 257 3600 Fax 507 257 3001 www micro trak com trakmail micro trak com Copyright 2006 Micro Trak Systems Inc...

Reviews: