Calibration
English or Metric?
The FlowTrak II is capable of displaying in for ma tion in
Amer i can En glish or standard Metric or Turf measurement
units. The FlowTrak II is shipped from the factory programmed
for English.
Note that the following procedures will also
load factory default calibration values.
To simply change
units without loading defaults, see the “Special Calibration”
section.
METRIC
• To activate the Metric mode, turn power OFF and place
the ro ta ry switch at
“AREA.”
Hold down both the
“CAL”
and “-”
keys and turn power ON.
See Il lus tra tion 10.
The
con sole will display LOAd for two seconds. Once LOAd
is displayed, release the two keys. To “lock-in” Metric
mode you must enter and exit cal i bra tion. You must be
in HOLD to enter Cal. Press and hold the CAL key until
“CAL” icon appears on the display. The con sole is now
in cal i bra tion and Metric mode is selected. Exit CAL by
pressing and holding the “CAL” key until CAL disappears
from the display (ap prox i mate ly 1 second).
NOTE: You
must exit CAL to lock in Metric units.
ENGLISH
• To activate the English mode, turn power OFF and
place the ro ta ry switch in the
VOLUME
position
.
Hold
down both the
“CAL” and “-”
keys and turn power ON.
The con sole will display LOAd. Once LOAd is displayed,
release the two keys. To “lock-in” English mode you
must enter and exit cal i bra tion. You must be in HOLD
to enter Cal. Press and hold the CAL key until “CAL”
lights on the display. The console is now in cal i bra tion
and English mode is selected. Exit CAL by pressing and
holding the “CAL” key until CAL disappears from the
display (approximately 1 second).
NOTE: You must exit
CAL to lock in English units.
IN ALL CALIBRATION OPERATIONS:
1. Put system in “HOLD”.
2. Press and hold the “CAL” key for 1 sec ond to select the
cal i bra tion mode. The con sole dis play will display the
“CAL” icon, the currently selected calibration value, and
the red warn ing light will turn on.
3. Turn the rotary dial to the desired “CAL” po si tion. Then
use the “+” or “-” key to adjust the dis played val ue up
or down as needed. Adjust ALL necessary values.
See
Illustration 11.
4. Hold the “CAL” key again for 1 sec ond to exit calibration.
“CAL” will disappear from the dis play.
NOTE: You must
exit CAL to save changes.
NOTE: In metric, the width will have a decimal point, in
English there is no decimal point. Also, changing from
En glish to Met ric mode may change or alter any previously
en tered cal i bra tion values. After switch ing mea sure ment
modes, con firm that all cal i bra tion val ues are correct.
Press to enter or exit
calibration mode.
Press to increase or
decrease values.
Red warning light will be
lit when in CAL.
WIDTH
CAL
FLOW
CAL
MIN
FLOW
TARGET
RATE
SPEED
CAL
TEST
SPEED
VOLUME /
MINUTE
DISTANCE
AREA /
HOUR
VOLUME
(1) (2) (3)
RATE
SPEED
AREA
(1) (2) (3)
CAL
RESET
TANK
II
TANK
VOL
TANK
ALARM
RUN
HOLD
CALHOLD
Illustration 10
Illustration 11
Summary of Contents for FLOWTRAK II
Page 1: ...Application Monitor Reference M a n u a l...
Page 36: ...Appendices 36...
Page 43: ......