RFT9709 Transmitter Instruction Manual
39
Appendix
A
RFT9709 Specifications
Performance specifications
Sensor model
Mass flow accuracy
1
ELITE
liquid
gas
±0.10% ± [(zero stability / flow rate) x 100]% of rate
±0.50% ± [(zero stability / flow rate) x 100]% of rate
BASIS
liquid
gas
±0.20% ± [(zero stability / flow rate) x 100]% of rate
±0.70% ± [(zero stability / flow rate) x 100]% of rate
D (except DH38), DT and DL
liquid
gas
±0.15% ± [(zero stability / flow rate) x 100]% of rate
±0.65% ± [(zero stability / flow rate) x 100]% of rate
DH38
liquid
gas
±0.15% ± [(zero stability / flow rate) x 100]% of rate
±0.50% ± [(zero stability / flow rate) x 100]% of rate
Sensor model
Mass flow repeatability
1
ELITE
liquid
gas
±0.05% ± [½(zero stability / flow rate) x 100]% of rate
±0.25% ± [(zero stability / flow rate) x 100]% of rate
BASIS
liquid
gas
±0.10% ± [½(zero stability / flow rate) x 100]% of rate
±0.35% ± [(zero stability / flow rate) x 100]% of rate
D (except DH38), DT and DL
liquid
gas
±0.05% ± [½(zero stability / flow rate) x 100]% of rate
±0.30% ± [(zero stability / flow rate) x 100]% of rate
DH38
liquid
gas
±0.05% ± [½(zero stability / flow rate) x 100]% of rate
±0.25% ± [½(zero stability / flow rate) x 100]% of rate
Sensor model
Density accuracy
Density repeatability
ELITE (except high-pressure CMF010P)
liquid
gas
±0.0005 g/cc
±0.002 g/cc
±0.0002 g/cc
±0.001 g/cc
ELITE high-pressure CMF010P
liquid
gas
±0.002 g/cc
±0.008 g/cc
±0.001 g/cc
±0.004 g/cc
BASIS
liquid only
±0.002 g/cc
±0.001 g/cc
D6, D12, D25, D40,
DH100, DH150
liquid only
±0.002 g/cc
±0.001 g/cc
DH6, DH12,
DH38
liquid only
±0.004 g/cc
±0.002 g/cc
D65, DL65, DT65,
D100, DT100,
D150, DT150, DH300
liquid only
±0.001 g/cc
±0.0005 g/cc
D300, D600,
DL100, DL200
liquid only
±0.0005 g/cc
±0.0002 g/cc
Sensor model
Temperature accuracy
Temperature repeatability
All sensors, Micro Motion sensor RTD
±1°C ± 0.5% of reading in °C
±0.02°C
All sensors, user-supplied sensor RTD
2
±0.5°F
±0.04°F
1
Flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. All specifications for liquids are based on
reference conditions of water at 68 to 77 °F (20 to 25°C) and 15 to 30 psig (1 to 2 bar), unless otherwise noted. For values of zero
stability, refer to product specifications for each sensor.
2
The user can install an external temperature detector, for the sensor, that is accurate to within ±0.1°F. Temperature accuracy
within ±0.5°F is required for API.
09specs.fm Page 39 Tuesday, March 2, 1999 9:30 AM
Summary of Contents for Fisher-Rosemount RFT9709
Page 1: ...Model RFT9709 Transmitter Instruction Manual March 1999 ...
Page 2: ......
Page 4: ......
Page 8: ...iv RFT9709 Transmitter Instruction Manual ...
Page 34: ...26 RFT9709 Transmitter Instruction Manual ...
Page 52: ...44 RFT9709 Transmitter Instruction Manual ...
Page 60: ...52 RFT9709 Transmitter Instruction Manual ...
Page 62: ...54 RFT9709 Transmitter Instruction Manual ...
Page 72: ...64 RFT9709 Transmitter Instruction Manual ...
Page 73: ......