4
RFT9709 Transmitter Instruction Manual
Mounting
continued
1.2
Mounting options
The RFT9709 has these installation options for mounting on any flat
surface:
• For mounting in a user-supplied NEMA-4 (IP65) enclosure
• Pre-installed by the factory in an optional NEMA-4 (IP65) enclosure
1.3
Installation in user-
supplied enclosure
• Install the RFT9709 with two screws to a flat mounting surface. Micro
Motion does not supply mounting screws.
• Install with wiring terminals facing away from the mounting surface.
• RFT9709 dimensions are provided in Figure 1-2.
Figure 1-2. RFT9709 dimensions
1 13/16
(46)
Dimensions in
inches
(mm)
1 11/32
(34)
3 5/32
(80)
Mounting boss
Use #8-32 (M4)
screws with flat
washers and lock
washers for
mounting
2X
6 1/8
(156)
2 15/16
(74)
3 1/4
(83)
2X
2X
5 9/16
(141)
Minimum
clearance
to open
access cover
5 1/4
(134)
Mounting
boss
2X
09mount.fm Page 4 Monday, March 1, 1999 4:28 PM