855-4JOETAP
/
(866) 327-4159
/
MICROMATIC.COM JOETAP
®
BARISTA INSTALLATION, USE & MAINTENANCE GUIDE
|
21
ROUTINE MAINTENANCE & CLEANING
DAILY
• Wipe down and clean all surfaces with warm soapy water.
– Refrigerated product storage area.
– Exterior surfaces of the system including beneath the unit and the drip tray
(if applicable).
• Clean stout faucet nozzles by removing and soaking in approved sanitizer/cleaner or
carbonated water.
EVERY TWO WEEKS
• Clean system following Routine Cleaning Procedure.
QUARTERLY
• Clean inlet condenser coil and check ice/water bath level.
BI-ANNUALLY
• Change air compressor inlet filter and coalescing filter.
ROUTINE CLEANING PROCEDURE
MATERIALS
• Rubber gloves
• Eye protection
• JoeTap
®
pre-mixed Bag-in-Box cleaner • Bucket
CLEANING
• Locate JoeTap
®
Bag-in-Box cleaner. This product is premixed and should not be diluted.
• Disconnect the Bag-in-Box product (if applicable).
• Attach the Bag-in-Box cleaner to the system.
• Turn ON the product pump button and turn OFF the water pump button.
• Open still faucet to begin introducing the cleaner into the system.
– Dispense 8
OZ
of cleaner, turn ON the water button, dispense for five seconds,
turn OFF the water pump button, and continue to dispense 8 more ounces of
undiluted cleaner.
– Close the faucet, wait at least five seconds, and turn OFF the product pump button.
– Allow the cleaner to soak in the line for at least five minutes.
• Turn ON the product pump button and open still faucet again.
– Dispense 8
OZ
of cleaner, turn ON the water button, dispense for five seconds,
turn OFF the water pump button, and continue to dispense 8 more ounces of
undiluted cleaner.
– Close the faucet, wait at least five seconds, and turn OFF the product pump button.
– Allow the cleaner to soak in the line for at least five minutes.
• Turn ON the product pump button and open nitro faucet.
– Dispense 8
OZ
of cleaner, turn ON the water button, dispense for five seconds,
turn OFF the water pump button, and continue to dispense 8 more ounces of
undiluted cleaner.
– Close the faucet, wait at least five seconds, and turn OFF the product pump button.
– Allow the cleaner to soak in the line for at least five minutes.
WARNING
When using cleaning fluids
or chemicals, rubber gloves
and eye protection should
be worn.