background image

12   

|   JOETAP

®

 BARISTA INSTALLATION, USE & MAINTENANCE GUIDE         855-4JOETAP  

/

  (866) 327-4159  

/

  MICROMATIC.COM

FILL CHILLER WATER/ICE BATH

•  Fill the water/ice bath with 2 gallons of water.
       –  Water/ice bath should be filled using sight glass tube on the front of the chiller. 

            

NOTE:

  Sight glass tube accessed by opening dispenser door and removing two Phillips 

head screws from white plastic shroud covering the face of the chiller.

•   Once the water/ice bath is full, water should begin flowing through the ice/water bath 

overflow drain line. If not, continue filling slowly until water begins to flow.

INSTALL FAUCETS

•   Install faucets on the door.
       –   Locate one of the two included stout faucets insert into either of the sockets on the 

door. Using a spanner wrench, tighten the collar on the door socket until faucet is 
tight and cannot spin freely. The collar must be turned counterclockwise to tighten 
the faucet. Repeat this step for the second faucet.

             

NOTE:

 Faucet handles should be perpendicular (at 12 o’clock) in relation to the   

countertop once tightened.

       –  Locate the two black tap handles and thread them onto the handles of the faucets.

       –   Ensure that both faucets are closed (handles pointed up and perpendicular to  

the counter).

PLUMB WATER SUPPLY LINE

•   

Plumb water line to the unit following all criteria outlined in Installation Location 
Requirements (section 5).

       –   Plumb water line with an in-line shutoff, back flow prevention device and water 

filter (if the plumber has not already done so), in accordance with criteria outlined 
in Installation Location Requirements (section 5) and in conformance with national 
and local codes.

 

 

–  If applicable, install Eltek® Water Block in-line.

•   Upon turning in-line water shutoff valve to the ON position, observe the unit and all 

connection points for leak(s).

       –   If there are any apparent leaks, immediately turn OFF and disconnect the water 

supply, turn OFF and unplug the unit, and fix the water leak(s) before proceeding.

            

NOTE:

  Ensure the unit is fully reassembled to the manufacturer’s specifications before 

reinstalling and reestablishing water and power connections.

ELECTRICAL CONNECTIONS

•   Plug the unit into electrical outlet meeting all electrical requirements outlined on unit 

name label and in Installation Location Requirements (section 5).

WARNING

All wiring and plumbing must 

conform to national and 

local codes.

WARNING

JT-CTMG must be electrically 

grounded to avoid possible 

fatal electrical shock 

or serious injury to the 

operator. 120V JT-CTMG 

power cord is equipped 

with a 3-prong plug. If 

supply cord is damaged it 

must be replaced by the 

manufacturer or its service 

agent or a similarly qualified 

person in order to avoid a 

hazard.

WARNING

Risk of electrical shock. 

Connect to a properly 

grounded outlet only.

Summary of Contents for JOETAP JT-CTMG

Page 1: ...AP BARISTA SAFETY FIRST READ INSTRUCTIONS COMPLETELY Before getting started please read this user manual and at all times follow the important safety instructions INSTALLATION USE MAINTENANCE GUIDE JT...

Page 2: ...2 JOETAP BARISTA INSTALLATION USE MAINTENANCE GUIDE 855 4JOETAP 866 327 4159 MICROMATIC COM...

Page 3: ...TY PROCEDURAL NOTICES 4 RECEIVING INSPECTING 6 SPECIFICATIONS 6 DIMENSIONS 7 COMPONENTS 8 LOCATION INSTALLATION 9 MAKING ADJUSTMENTS 15 GENERAL OPERATION 20 ROUTINE MAINTENANCE CLEANING 21 TROUBLESHOO...

Page 4: ...se notices supply helpful information which may assist you as you work Throughout this manual you will see the following types of procedural notices NOTE Text set off as a Note provides you with simpl...

Page 5: ...CAUTION Proper installation care and maintenance are essential for maximum performance and trouble free operation of your equipment Read and understand this manual It contains valuable care and mainte...

Page 6: ...rs before plugging into power source WARNING PERSONAL INJURY POTENTIAL Do not operate equipment that has been misused abused neglected damaged or altered modified from that of original manufactured sp...

Page 7: ...fied service technician must perform installation and start up of this equipment If you cannot or are not qualified to correct the service problem call your service provider or distributor Always have...

Page 8: ...TROL PANEL SYSTEM ON OFF INDICATOR LIGHT GENERATOR ON OFF INDICATOR LIGHT VOLTAGE REGULATOR GAUGE N2 REGULATOR ADJUSTMENT SCREW SCHOLLE BIB CONNECTOR FITTING STILL FAUCET WATER FLOW CONTROL VALVE NITR...

Page 9: ...eter and be closed sealed once the power cord drain line and water supply line are in place and connected Avoid placing the dispenser near heat sources such as radiators ovens refrigeration equipment...

Page 10: ...onnected appliance the following shall be included Do not unplug by pulling on cord To unplug grasp the plug not the cord Unplug from outlet when not in use and before servicing or cleaning Do not ope...

Page 11: ...er peristaltic pump gearbox speed 172 RPM or 282 RPM tubing inside diameter 1 8 3 16 or 1 4 and voltage 12V 22V If a unit is equipped with a peristaltic pump tube diameter and gearbox combination that...

Page 12: ...ing all criteria outlined in Installation Location Requirements section 5 Plumb water line with an in line shutoff back flow prevention device and water filter if the plumber has not already done so i...

Page 13: ...djustments usually only 1 2 PSI are required to achieve smooth flow NOTE See Adjusting Still Water Flow Control Valve section 6 to determine how to properly adjust the still faucet water flow rate PRI...

Page 14: ...trol valve accordingly NOTE See Adjusting Still Water Flow Control Valve section 6 to determine how to access and properly adjust the still water flow control valve Continue to pour full servings take...

Page 15: ...staff if applicable NOTE Only trained and certified technicians should make adjustments to this system NOTE Any time an adjustment is made to brix or level of N2 infusion 12 OZ of liquid must be poure...

Page 16: ...w fast the pump motor spins RPM and how much liquid can be displaced flow rate for a given tubing diameter and gearbox The voltage regulator should be set no lower than 12V If the proper flow rate can...

Page 17: ...water flow control should not occur until nitro faucet has been fully calibrated NOTE As a point of reference the nitro faucet has a constant water flow rate of about 1 OZ SEC To achieve a still drin...

Page 18: ...et likely needs adjusted Remove the lid nitrogen generator chassis insulation board to access pressure switch in question Using a 05 Hex Key turn the adjustment screw counterclockwise Continue making...

Page 19: ...cessary product flow rate is 1775 ML MIN 5 355 ML MIN Choose a pump package that is close to but exceeds the calculated product flow rate NOTE See Peristaltic Pump Flow Rate chart below In the case of...

Page 20: ...t and remove white cap from the fitting If applicable disconnect empty Bag in Box and dispose of it appropriately Rinse connector using a small cup of warm water Attach Bag in Box connector to fitting...

Page 21: ...begin introducing the cleaner into the system Dispense 8 OZ of cleaner turn ON the water button dispense for five seconds turn OFF the water pump button and continue to dispense 8 more ounces of undi...

Page 22: ...x priming process 3 Contact authorized service agent or perform cleaning in accordance with Routine Cleaning Procedure if authorized to do so 4 See Making Adjustments to determine how to properly adju...

Page 23: ...sure both of the green power switches on the chiller are turned ON and illuminated 2 See Refrigeration Check in Installation to determine how to properly view and set the temperature for the chiller 3...

Page 24: ...ress and hold down the gas out button for two seconds and release Wait for the Nitrogenator to build pressure and shut off Press and hold down the gas out button for two seconds and release Wait for t...

Page 25: ...855 4JOETAP 866 327 4159 MICROMATIC COM JOETAP BARISTA INSTALLATION USE MAINTENANCE GUIDE 25 NOTES...

Page 26: ...vered by the foregoing warranties for the remainder of the original Warranty Period or ninety 90 days from the date of delivery of the repaired or replaced Product whichever is longer All shipments wi...

Page 27: ...rchaser shall have no right to use any trademarks owned or licensed to Micro Matic without the express written permission of Micro Matic RELEASE AND INDEMNITY By operating this Product the Purchaser h...

Page 28: ...27 4159 MICROMATIC COM Info JoeTap com 855 4JoeTap 855 456 3827 joetap com NationalAccounts Micro Matic com 866 327 4159 micromatic com joetap 01857 D0717 2017 Micro Matic USA Inc All Rights Reserved...

Reviews: