Page 16
Installation and Assembly
surfaceCONTROL 3D SC2500 / SC2510
5.2
Mounting Adapter
The sensor is attached either to a tripod, a robot or a portal.
For mounting the sensor on a tripod or a robot, corresponding mounting adapters (matt black anodized) are provided as
separate accessories, see
.
The sensors are optical sensors that operate in the µm range.
Ensure careful handling during installation and operation.
Damage to or destruction of the sensor
The mounting adapters are always fastened to the sensor base with a total of 6 M6 screws. A metal pin on the underside
of the sensor is used for unambiguous orientation of the adapter.
Mount the sensor to the mounting adapter ensuring full contact over the entire surface.
21.65 (.85)
0
25 (.98)
21.65 (.85)
12.5
(.49)
0
12.5
(.49)
25
(.98)
25
(.98)
ø6 H7
ø40 H8
6x M6
A
A
Fig. 8 Mounting dimensions of flange adapter, dimensions in mm (inches)
The sensor and mounting adapter must not be tilted to one another. All screws must be tightened. An improperly mount-
ed adapter can cause the accurately reproducible positioning of the sensor to be impaired and the sensor, adapter and
tripod connecting elements to be unevenly mechanically stressed.