Page 59
Setting Sensor Parameters
optoNCDT 1900 / EtherCAT
Timestamp
32 Bit
x
Digital value
[0; 4294967295]
t
=
x
1
1000
t
Time stamp in µs
[0; 1h11m34.967s]
Unlinearized
center of grav-
ity
18 Bit
x
Digital value
[0; 262143]
US
=
x
100
262143
CG
Center of gravity in %
[0; 100]
Measurement
frequency
18 Bit
x
f
Digital value
Frequency in Hz
[2500; 100000]
f
=
x
10
State information transferred in the distance value
Distance value
Description
262076
No peak
262077
Peak is before measuring range (MR)
262078
Peak is after measuring range (MR)
262080
Measurement value cannot be evaluated
262081
Peak is too wide
262082
Laser is off
Summary of Contents for ILD1900-10