Environment
Cycle Operation
Auto Fan Operation
Inside
≥
Setpoint
None
Off
Inside 1° Or More Below Setpoint
Furnace Stage #1 On
Inside Returns 1° Above Setpoint
Furnace Stage #1 Off
Table 7 - Furnace Only Mode Operation
Note:
operation may be different based on the Gap settings. See section
for details.
Note: All heat modes are subject to
Auto Gas Changeover Operation when enabled. See section
in
Auto Modes
These modes will automatically switch between
heating and cooling cycles as needed. Their operation will
be the same as their “only” mode counterparts
described
earlier in the
have their own
“dual” set
-points that are separate heating
and cooling set-points. No heating or cooling cycles will
occur when the inside temperature is between the set-
points.
This can be useful when setting a higher day-time
cooling temperature and lower night-time heating
temperature. It can also be used to control the
temperature extremes when you are away from the RV.
shows how the main screen will look in auto mode.
Note: These auto modes are subject to
Auto Gas
Changeover and Gap operations. See their
sections
respectively for more details.
(1) Auto Mode Set-Points
Press the set-points to toggle between which set-point you
have selected. A blue square will show around the one you
have selected. The upper set-point is for cooling and the
lower set-point is for heating.
(2) Set-Point Adjustment
Use the up and down arrows to change the selected set-point value.
Figure 2 - Auto Mode Main Screen
Auto Cool/Heat Pump Mode
Auto Cool/Furnace Mode