HIQ 424   

Programmable Wireless Thermostat  

Range up to 30m inside dwelling 
Power two x AA batteries 
Range 5 to 50 deg C 
 
Functional Description 
1 = Power - on / Anti frost /off      5 = Reset (use pin)

 

 

2 = Time setting                               6 = Plus/add 
3 = Program setting                        7= Minus/lower 
4 = Confirm/ Exit  
 

Press Power on 

 

Set Time/day 

Press 

2

 to enter setting -   time - use up and down to set current minutes -

3

 – hour -  

3

  day  -  Press 

4

 to confirm and exit. 

 

Programing         The default for this unit is 7 Days 6 set points  

All seven days need to be programmed in using the following method the pattern can be different for each day of the week  

Using button 

1

 select Using Schedule, 

temperature will display in top right f screen with using schedule below. 

 

Press 3 -  set day – press 3 set switching time for period 1– press 3 - set temperature required for period 1  
Press 3 - again to move on to period 2 and so on-  set as required until all six daily switch times are set  
Press 4-  to finish and lock in settings 

 

                                                                                        

Use this chart to set our your chosen programming before entering 

Set point 

Get up 

Deg  

Out to 
work 

Deg  

Lunch 
home 

Deg  

Lunch 
out 

Deg 

Evening 
home 

Deg 

Bedtime  Deg 

Example 

06.30 

19 

09.00 

15 

11.45 

19 

12.45 

15  

16.00 

21  

21.30 

7  

Monday 

 

 

 

 

 

 

 

 

 

 

 

 

Tuesday 

 

 

 

 

 

 

 

 

 

 

 

 

Wednesday 

 

 

 

 

 

 

 

 

 

 

 

 

Thursday 

 

 

 

 

 

 

 

 

 

 

 

 

Friday 

 

 

 

 

 

 

 

 

 

 

 

 

Saturday 

 

 

 

 

 

 

 

 

 

 

 

 

Sunday 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Permanent override  

To permanently set a temperature press 3- for 3 seconds to enter permanent hold -  set using 6-7 (up down) 
The thermostat will hold this temperature until you press- 4 to escape permanent mode. 

 

Temporary override. 

In normal operation simply use 6-7 (up/down) to change the set temperature the temperature selected will remain until the 
next switching point.  

 
Battery low 

A battery symbol will flash for up to 30 days  until the battery is replaced Replace the batteries with two AA as soon as possible. 
Key lock 

Reset to factory default   

      

Press and hold - 4 for three  or more seconds  

Full reset

    

-      if the display becomes scrambled use a paperclip to press -5 

Key lock

 

– Press and hold up down keys for three seconds- repeat to release 

 

More information including advanced 
programming can be obtained from the 
detailed instructions included 