HLP-SERIES Hot Water Pressure Washer Operator's Manual
maintenance instructions
preVentiVe operator maintenance cHart
dealer maintenance cHart
PROCEDURE
DAILY
3 MONTHS 6 MONTHS
9 MONTHS 2 MONTHS
Gas leak inspection
X
Water leak inspection
X
Oil leak inspections
X
Quick-connect and hose inspection
X
Check pump oil level
X
*Change pump oil
X
X
X
X
Check belt tension
X
X
X
X
Replace high pressure nozzle
X
X
X
X
Test water pressure
X
X
Test water temperature
X
X
*The pump oil must be changed after the first 50 hours of operation and every 250 hours or 3 months,
whichever comes first.
PROCEDURE
2 MONTHS
Gas supply inspection
X
Clean gas line drip legs
X
Burner inspection
X
Exhaust ventilation inspection
X
*Descale coil
X
Test Voltage & Amp Draw
X
*Scale buildup will vary with mineral content in the
water and amount of usage. Descaling can range
from monthly to yearly maintenance.