7
preparation instructions
pre-start:
. Before lighting, smell all around the machine for gas. Especially, sniff
the floor area because L.P.-Gas is heavier than air and will settle on the
floor. Do not operate unit if smell exists. Leave the location and contact
a qualified serviceman.
2. Check to ensure the unit is plugged in.
3. Pump oil level should be checked before each use. The proper oil level
should be at the notch on the dipstick. If the level appears low, use
Mi-T-M pump oil #AW-4085-006.
unloader:
Hlp-0703-0m10:
The unloader has an adjustment knob which has a
minimum/maximum setting. Turn the unloader knob
clockwise to the maximum setting for Cold/Hot water
operation. Turn counterclockwise to minimum setting for
Steam operation.
Hlp-1502-0m10:
The unloader has been preset at the factory and should
only be adjusted by a trained serviceman.
Hlp-0703-0m10
risK of eXplosion or fire!
DANGER
smell for Gas before
startinG unit. alWays sniff
area around tHe macHine
for a Gas smell. be sure to
sniff floor area, since l.p.-
Gas is HeaVier tHan air and
Will settle on tHe floor.
if you smell Gas:
•
do not start unit and turn
off Gas supply.
•
do not operate any
electrical sWitcH.
•
do not liGHt any
appliance.
•
do not use any pHone in
tHe room or area.
•
leaVe, Go to anotHer
location and use a pHone
to call your Gas supplier.
•
folloW tHe Gas supplier's
instructions.
•
if you cannot reacH your
Gas supplier, call tHe fire
department.
risK of fire or eXplosion!
y o u m u s t f o l l o W
instructions eXactly, a fire
or eXplosion may result
causinG property damaGe,
personal inJury or loss
of life.
WARNING
attire:
Proper attire is essential to your safety. It is advised to utilize whatever means
necessary to protect eyes, ears, and skin. Additional safety attire (such as
respiratory mask) may be required when using detergent cleaning agents with
this pressure washer.
YES NO