8
79D0004
Lo-Rider Designer Vent Free Fireboxes
loCation of firebox
Carefully select the best location for installation of your vent-free firebox. The following factors should be
taken into consideration.
•
Clearance to side wall, ceiling, woodwork, and windows. Refer to “ClEARANCES and HEIgHT
REQUIREMENTS” section below and on pages 8 and 9. Minimum clearances to combustibles
must
be maintained.
•
location must not be affected by drafts caused by kitchen exhaust fans, ceiling fans, return air registers
for forced air furnaces/air conditioners, windows, or doors.
•
Installation must provide adequate ventilation and combustion air.
•
Do not install this firebox in a bathroom.
•
This firebox enclosure is approved for bedrooms on the condition that the unvented room heater does
not exceed 10,000 BTUs input and the room is properly sized for combustion air.
•
location should be out of high traffic or windy or drafty areas.
•
Do not install Where Curtains, furniture, ClothinG or other flammable
obJeCts are less than 36" from front of heater.
•
Never obstruct the front opening of the vent-free firebox or restrict the flow of combustion and ventila-
tion air.
•
Minimize modifications to existing construction.
Refer to Figure 2
for location suggestions.
•
Do not install in the vicinity where gasoline or other flammable liquids may be stored. The vent-free
firebox must be kept clear and free from these combustible materials.
Figure 2 -
Suggested Firebox Locations
Corner Left
Corner Left
Peninsula
See-through
Corner Right
Corner Right
FP2318
designer locate
FP2318