Mod. IC
Version 01
Page 27-34
5.9 FAULT REPORT
Fault shown in display Cause
Corrective measures
Clean optical sensor
Light barrier covered
Press any button
Error: Motor > grd.C
Control amplifier board
stepper motor overheated
See enclosed manual
Do not turn off machine and
wait 15 min. to let the
machine cool down
Frequency converter main
motor overheated
See enclosed manual
Do not turn off machine and
wait 15 min. to let the
machine cool down
Frequency converter
conveyor belt overheated
Orange LED lights up
Do not turn off machine and
wait 15 min. to let the
machine cool down
Error
Product to be cut is too short
for the programme
Enter new figures
Error: Limit switch
Limit switch is covered
Replace defective reed
switch
Error button „
Description
“
Button „
Description
“ defective
Replace button
In the case, however, that disruptancies do occur, then you should without question
contact your dealer or our service division.
MHS Schneidetechnik GmbH
Seestraße 7
D-74232 Abstatt
Tel.: 07062 / 91 08 40
Fax: 07062 / 91 08 42
The service division or contact workshop will require the following information:
type of disruptancy
machine type/make
machine number
type/nature of the defective part
In this way it can be guaranteed that repairs, if called form, are carried out from
knowledgeable technicians in the shortest period of time